beautypg.com

12 signal ground switch, Installation and connection – Naim Audio NDS User Manual

Page 8

background image

7

6

Installation and Connection

be carried out. Contact your retailer for more information
if required.

Note:

The rear panel mini-USB socket is not intended for the

connection of USB storage hardware and cannot be used
for audio playback.

2.12 Signal Ground Switch

The NDS is fitted on its rear panel with a

Signal Ground

switch offering two positions:

Chassis

and

Floating

. Select

the

Chassis

position unless NDS is connected in a hi-fi

system incorporating another earthed source component,
or mains “hum” is audible through the loudspeakers.
Contact your retailer, distributor or Naim for advice if
necessary.

Note:

“Connected” in the context above means an

analogue audio signal cable that includes an earth
connection.

Note:

All Naim CD players are earthed so the Signal

Ground switch should be set to floating if one is connected
in the system (unless a digital signal connection is used).

No damage will be done if the wrong Signal Ground
position is chosen, however the system sound quality may
be compromised.

2.12.1 General Audio Connection Notes

The NDS power supply mains earth (ground) should always
be connected regardless of what other equipment is used.

Note:

As an external power supply is used the NDS mains

earth is connected through the Burndy connection cable
to the power supply mains earth.

A mains earth grounds the chassis and the electrostatic
screen within the power supply transformer, and is only
connected to the signal negative if the

Signal Ground

switch is set to

Chassis

. In order to avoid hum loops, the

signal negative of the whole system should be connected
to the mains earth in one place only.