Nexen ROP 964538 User Manual
Page 8

FORM NO. L-21200-C-0613
8
OPERATION
AUTOMATIC/MANUAL MODE SELECTION
When the AUTO key is depressed the RSTC will go into
automatic mode; the RSTC Status display will change to
“Auto” to confirm that the RSTC is in automatic mode. At
this stage, the web’s tension is set by the Tension Adjust
knob and maintained automatically.
When the MANUAL key is depressed the RSTC will go
into manual mode; the RSTC Status display will change
to “Man” to confirm that the RSTC is in manual mode. At
this stage, the Tension Adjust knob is used to manually
change the RSTC’s control output level.
Web Tension/Output Level Adjustment And Indication
AUTOMATIC MODE
When the RSTC is in automatic mode (status display
indicates “Auto”) the tension setpoint is adjusted by
turning the Tension Adjust knob. Turning the knob
clockwise will increase the setpoint and turning the knob
counterclockwise will decrease the tension setpoint.
Turning the knob will cause the ROP display to change
from the RSTC Status screen to the Job Setup screen (See
Figure 8). Continue turning the knob until Web Tension
Setpoint is set to the desired tension value. If the knob
is left stationary, the ROP display will return to the RSTC
Status screen after a short delay.
Web tension is indicated by the TENSION display (See
Figure 7). The bar graph display indicates web tension
magnitude as a percentage of the RSTC’s maximum
tension setpoint value entered during RSTC setup.
Job: 03 Job Loaded
Delay: 5.0 in
Taper: 12
Tension SP: 234 lb
Web Tension
Setpoint
Job Loaded/Job
Saved Message
Taper Tension
Delay
Taper Tension
Setpoint
Job Selection
Figure 8
Job Setup Screen
TENSION
+
+
RSTC Status/Job
Setup Display
Communication
Error Indicator
Communication
Indicator
Load Job
Save Job
Job Selection
Taper Delay Adjust
Taper Adjust
Alarm
Acknowledge
Tension
Adjust
Load Cell
Selection
Control Output
ON/OFF
Automatic
Mode
Manual Mode
Figure 6
Figure 7
RSTC Status Screen
Tension: 82.7 lb
Output: 21% Dia: 32.5
Status: Auto Stop
RSTC
Status
Auto/Man
Stop/Run
Roll
Diameter
Alarm
Message
Tension/Output
Level Bar Graph
Web Tension
Control Output
Level