RSD200 REGISTER MEMORY MAP

REGISTER ADDRESS

DESCRIPTION

HMI FUNCTION

SETUP

10

Restore Default Values

Write Only

11

Load Communication Parameters

Write Only

12

Stop Bits: 1, 2

Read & Write

13

Device Address: 1247

Read & Write

14

Baud Rate: 9600, 19200, 38400

Read & Write

15

Parity: 0–none, 1–odd, 2–even

Read & Write

16

Torque Actuator: 1–brake, 2–drive

Read & Write

17

Application: 1–unwind, 2–wind

Read & Write

18

Minimum Output: 0–100%

Read & Write

19

Maximum Output: 0–100%

Read & Write

20

Stopped Output: 0–100%

Read & Write

CALIBRATION

D

ANCER

R

ANGE

21

Read Maximum Storage Position

Write Only

22

Read Minimum Storage Position

Write Only

W

EB

T

ENSION

23

Minimum Arm Pressure: 1.0–100.0 psi

Read & Write

24

Minimum Web Tension: 1.0–500.0 lbs

Read & Write

25

Maximum Arm Pressure: 1.0–100.0 psi

Read & Write

26

Maximum Web Tension: 1.0–500.0 lbs

Read & Write

T

UNING

27

Gain: 0.1–10.0

Read & Write

28

New Roll Adaptation: 2–100

Read & Write

29

Setpoint: 1–100%

Read & Write

30

Dampening: 1–7

Read & Write

31

Minimum Adaptation: 2–20

Read & Write

32

Maximum Adaptation: 2–100

Read & Write

33

Adaptation Rate: 2–50

Read & Write

C

ONTROL

34

Web Run/Stop: 0–stopped, 1–running

Read & Write

35

Splice: 1–splice, reset adaptation

Read & Write

36

Auto/Man: 1–manual, 2–automatic

Read & Write

37

Output: 0–100%

Read & Write

38

Dancer Position: 0–100%

Read Only

39

Adaptation: 0–100

Read Only

This manual is related to the following products: