Nexen RSD200 964533 User Manual
Page 6

FORM NO. L-21195-A-0904
6
RSD200 REGISTER MEMORY MAP
REGISTER ADDRESS
DESCRIPTION
HMI FUNCTION
SETUP
10
Restore Default Values
Write Only
11
Load Communication Parameters
Write Only
12
Stop Bits: 1, 2
Read & Write
13
Device Address: 1–247
Read & Write
14
Baud Rate: 9600, 19200, 38400
Read & Write
15
Parity: 0–none, 1–odd, 2–even
Read & Write
16
Torque Actuator: 1–brake, 2–drive
Read & Write
17
Application: 1–unwind, 2–wind
Read & Write
18
Minimum Output: 0–100%
Read & Write
19
Maximum Output: 0–100%
Read & Write
20
Stopped Output: 0–100%
Read & Write
CALIBRATION
D
ANCER
R
ANGE
21
Read Maximum Storage Position
Write Only
22
Read Minimum Storage Position
Write Only
W
EB
T
ENSION
23
Minimum Arm Pressure: 1.0–100.0 psi
Read & Write
24
Minimum Web Tension: 1.0–500.0 lbs
Read & Write
25
Maximum Arm Pressure: 1.0–100.0 psi
Read & Write
26
Maximum Web Tension: 1.0–500.0 lbs
Read & Write
T
UNING
27
Gain: 0.1–10.0
Read & Write
28
New Roll Adaptation: 2–100
Read & Write
29
Setpoint: 1–100%
Read & Write
30
Dampening: 1–7
Read & Write
31
Minimum Adaptation: 2–20
Read & Write
32
Maximum Adaptation: 2–100
Read & Write
33
Adaptation Rate: 2–50
Read & Write
C
ONTROL
34
Web Run/Stop: 0–stopped, 1–running
Read & Write
35
Splice: 1–splice, reset adaptation
Read & Write
36
Auto/Man: 1–manual, 2–automatic
Read & Write
37
Output: 0–100%
Read & Write
38
Dancer Position: 0–100%
Read Only
39
Adaptation: 0–100
Read Only