Alert Settings (Continued)

Setting Item

Description

Alarm Time

Configures the time to alert.

(Only Lamp Time Alarm and Filter Time Alarm.)

SNMP Trap

Click the

[Enable] check box to enable SNMP trap alerts.

Send Mail

Click the

[Enable] check box to enable e-mail alerts.

(Except

Cold Start and Authentication Failure.)

Mail Subject

Configures the subject line of the e-mail to be sent.

The length of the subject line can be up to 255 alphanumeric

characters.

(Except

Cold Start and Authentication Failure.)

Mail Text

Configures the text of the e-mail to be sent.

The length of the text can be up to 1024 alphanumeric

characters.

(Except

Cold Start and Authentication Failure.)

The Alert Items are shown below.

• The trigger of Filter Error e-mail is depending on the FILTER

MESSAGE setting in the SERVICE item of the OPTION menu which defines

the period until filter message is displayed on the projector screen. The e-mail

will be sent when the filter timer exceeds 50, 100, 200, 300, 400, 500, 600, 700

or 800 hours based on the configuration. No notification e-mail will be sent if the

FILTER MESSAGE is set to TURN OFF. ("OPTION menu" section of the User's

Manual - Operating Guide)

• Lamp Time Alarm is defined as a threshold for e-mail notification (reminder) of

the lamp timer. When the lamp hour exceeds this threshold that is configured

through the Web page, the e-mail will be sent out.

• Filter Time Alarm is defined as a threshold for e-mail notification (reminder)

of the filter timer. When the filter hour exceeds this threshold, the e-mail will be

sent out.

NOTE

Click the

[Apply] button to save the settings.