beautypg.com

Selector switch position 2 = cat-5a cable, Setting up the in-line network in detail – Delta TE-4000 User Manual

Page 26

background image

Setting up the In-Line network in detail


To set up the in-line network you must install the I/O PB-17 boards
into each terminal.

There are 2 types of In-line network selectable via a selector
switch, which can be found on the underside of the cash register

Selector switch position 1 = Casio In-Line (ARCNET)
Selector switch position 2 = Cat-5A Cable

Initialise the first terminal and the machine number will be
MC#01connect the Casio or Cat-5 cable to the white Casio
connector or the OUT port of Cat-5 board.


In-line cable

Master

Add the second cash register and plug the In-line cable into the
white Casio connector or the IN port of the Cat-5 board

Initialise the cash register and check that the terminal has been
recognised in the In-line network by checking that the MC# number
is MC#02

In-line

Master

Satellite


Add the third cash register to the network and plug the In-line
cable into the white Casio connector or the OUT port of machine 2
to the IN port of the Cat-5 board.

Initialise the cash register and check that the terminal has been
recognised in the In-line network by checking that the MC# number
is MC#03

Copy the above for machine 4 looking for MC#04 after initialisation

26