beautypg.com

Electrical – Ryobi RAP200 User Manual

Page 6

background image

6 — English

ELEcTRIcAL

GROUNDING INSTRUcTIONS

This product must be grounded. In the event of a malfunction
or breakdown, grounding provides a path of least resistance
for electric current to reduce the risk of electric shock.
This product is equipped with an electric cord having an
equipment-grounding conductor and a grounding plug. The
plug must be plugged into a matching outlet that is properly
installed and grounded in accordance with all local codes
and ordinances.
Do not modify the plug provided. If it will not fit the outlet,
have the proper outlet installed by a qualified electrician.

WARNING:

Improper connection of the grounding plug can result in a
risk of electric shock. When repair or replacement of the
cord is required, do not connect the grounding wire to
either flat blade terminal. The wire with insulation having
an outer surface that is green with or without yellow
stripes is the grounding wire.

Check with a qualified electrician or service personnel if
the grounding instructions are not completely understood,
or if in doubt as to whether the product is properly
grounded.
Repair or replace a damaged or worn cord immediately.
This product is for use on a nominal 120 V circuit and has
a grounding plug similar to the plug illustrated below. Only
connect the product to an outlet having the same configuration
as the plug. Do not use an adapter with this product.

EXTENSION cORDS

Use only 3-wire extension cords that have 3-prong grounding
plugs and 3-pole receptacles that accept the product’s plug.
When using a power tool at a considerable distance from
the power source, use an extension cord heavy enough to
carry the current that the product will draw. An undersized
extension cord will cause a drop in line voltage, resulting in
a loss of power and causing the motor to overheat. Use the
chart provided below to determine the minimum wire size
required in an extension cord. Only round jacketed cords
listed by Underwriter’s Laboratories (UL) should be used.

**Ampere rating (on product data plate)

0-2.0

2.1-3.4

3.5-5.0 5.1-7.0 7.1-12.0 12.1-16.0

cord Length

Wire Size (A.W.G.)

25'

16

16

16

16

14

14

50'

16

16

16

14

14

12

100'

16

16

14

12

10

**Used on 12 gauge - 20 amp circuit.
NOTE: AWG = American Wire Gauge

When working with the product outdoors, use an extension
cord that is designed for outside use. This is indicated by the
letters “W-A” or “W” on the cord’s jacket.
Before using an extension cord, inspect it for loose or
exposed wires and cut or worn insulation.

WARNING:

Keep the extension cord clear of the working area.
Position the cord so that it will not get caught on lumber,
tools, or other obstructions while you are working with a
power tool. Failure to do so can result in serious personal
injury.

WARNING:

Check extension cords before each use. If damaged
replace immediately. Never use the product with a
damaged cord since touching the damaged area could
cause electrical shock resulting in serious injury.

ELEcTRIcAL cONNEcTION

This product is powered by a precision-built electric motor. It
should be connected to a power supply that is

120 V, Ac only

(normal household current), 60 Hz. Do not operate this
product on direct current (DC). A substantial voltage drop
will cause a loss of power and the motor will overheat. If
the product does not operate when plugged into an outlet,
double check the power supply.

GroundinG

Pin

GFCi reCePtiCle