Heating/cooling cycle analysis, Heating cycle analysis, Cooling cycle analysis – WaterFurnace Envision Hydronic User Manual
Page 41: Nskw installation manual
![background image](/manuals/743412/41/background.png)
41
NSKW INSTALLATION MANUAL
Heating Cycle Analysis
Suction
Discharge
Compressor
RV
Source
Coax
FD
______kPa = ______SAT°C
______°C
______kPa = ______SAT°C
______°C
______°C Liquid Line
Unit Amp Draw
Line Voltage
Loop:
Open
Closed
Subcooling
Superheat
NOTE: Do not attach refrigerant gauges unless a problem is suspected!
Entering Source Water
°C
Entering Water Pressure
kPa
Leaving Source Water
°C
Leaving Water Pressure
kPa
Entering Load Water
°C
Entering Load Water Pressure
kPa
Leaving Load Water
°C
Leaving Load Water Pressure
kPa
Load
Coax
Suction
Discharge
Compressor
RV
Source
Coax
FD
______kPa = ______SAT°C
______°C
______kPa = ______SAT°C
______°C
______°C Liquid Line
Load
Coax
Unit Amp Draw
Line Voltage
Loop:
Open
Closed
Subcooling
Superheat
NOTE: Do not attach refrigerant gauges unless a problem is suspected!
Entering Source Water
°C
Entering Water Pressure
kPa
Leaving Source Water
°C
Leaving Water Pressure
kPa
Entering Load Water
°C
Entering Load Water Pressure
kPa
Leaving Load Water
°C
Leaving Load Water Pressure
kPa
Cooling Cycle Analysis