beautypg.com

Ubiquiti Networks airFibe5 User Manual

Page 31

background image

29

Alignment

6.

Slave

Aim the Slave at the Master to achieve the strongest

signal level on the Remote LED Display of the Slave.

Note:

Values on the LED Displays are displayed in

negative (-) dBm. For example, 67 represents a received
signal level of -67 dBm. Smaller numerical values indicate
stronger received signal levels. For example, a reading of
49 is stronger than a reading of 55.

Note:

Maximum signal strength can best be achieved

by iteratively sweeping through both azimuth and
elevation.

7.

Master

Aim the Master at the Slave to achieve the strongest

signal level on the Remote LED Display of the Master.

Note:

If the Overload LED lights up, refer to the

airFiber AF-5/AF-5U User Guide at:
documentation.ubnt.com/airfiber

8. Repeat steps 6 and 7 until you achieve a symmetric link, with

the signal levels within 1 dB of each other. This ensures the

best possible data rate between the airFiber radios.

GPS

MASTER

LINK

RESET

4X to 0.25X

OVERLOAD

8X
6X

REMOTE

LOCAL

AUX

MANAGEMENT

DATA

ACT

SPEED

ACT

SPEED

9. Lock the alignment on both airFiber radios by tightening the

nuts and bolts.

10. Observe the Local and Remote LED Displays of each airFiber

radio to ensure that the values remains constant while

tightening the nuts and bolts. If any LED value changes during

the locking process, loosen the nuts and bolts, finalize the

alignment of each airFiber radio again, and retighten the nuts

and bolts.

11. For each airFiber radio, close the port cover and ensure that the

Ethernet cable stays in the cable feed slot.