ADJUSTMENT PROCEDURE:
CAUTION:
Before making any adjustment let the unit heat-up at least 15 min.
Observe that the offset-voltage measured at the sidechain jack socket, when the
THRESHOLD is off, is not greater than +/- 15 mV DC in both position "fixed" and
"manual".
(tip is link 1 and ring is link 2).
If the voltage exceeds this value, replace either IC1 or IC2.
THE GRE (GR1) SHALL BE MARKED FROM 1.005 TO 1.175
ADJUSTMENT OF BASIC GAIN:
1)
Apply a signal of 1 kHz, -10,0 dBU into the input of the compressor.
2)
Turn the GAIN-control fully clockwise.
3)
Set the RATIO-control at 1,5:1
4)
Adjust the pre-set GAIN (
P1/P101 located
on amp/psu PCB) to an output-reading
of 0,0 dBU.
ADJUSTMENT OF COMPRESSION TRACKING:
1)
Turn the THRESHOLD-control fully counter-clockwise.
2)
Set the RATIO-control at 1,5:1.
3)
Set the LINK-switch at link 1.
4)
Apply a signal of 1 kHz, 0,0 dBU into the input of the compressor.
5)
Adjust the GAIN-control to an output-reading of 0,0 dBU.
6)
Apply a DC-voltage of +250,0 mV into the sidechain jack socket (tip) and observe that
the output level has dropped to -10,0 dB.
7)
If this is not the case, adjust the level with P 6 (-10dB), to obtain a drop of
exactly -10,0 dB.
(981214)