Tube Tech MMC 1A MIC Preamp and DI and multiband compressor User Manual
Page 6
Lydkraft ApS
Mose Allé 20, DK2610 Rødovre
Denmark
6
HIGH BAND:
1) Turn all the THRESHOLD-controls fully counter-clockwise.
2) Turn the HIGH BAND GAIN-control fully clockwise.
3) Turn the LOW BAND and MID BAND GAIN-control fully counter clockwise.
4) Set the X-OVER HIGH at 1,2k.
5) Apply a signal of 10 kHz, (approx. -20 dBU) to the input and adjust the input level
for an output reading of 0,0dBU.
6)
Move
t
he
j
umper
on
t
he
hi
gh
band
si
de
chai
n
PCB
(
t
op
most
PCB)
t
o
“
ADJUST”
and observe that the output level has dropped to -10,0 dBU.
7) If this is not the case, adjust the gain reduction with P61, to obtain a drop of -10,0 dB.
10) Adjust the high band display with P62 so the green -10 LED turns on and the
green -7 LED just turns off.
(041121)