ADJUSTMENT OF THE RELEASE CONTROL:
1)
Set the METER switch in position compression.
2)
Set the attack/release SELECT switch in position manual.
3)
Apply a signal of 1 kHz, 0,0 dBU into the input of the compressor.
4)
Adjust the THRESHOLD-control to a reading of -10 VU of the VU-meter
5)
Set the ATTACK-control at fast.
6)
Set the RELEASE-control at slow.
7)
Switch off the 1 kHz and observe that the VU meter moves to 0 VU in approx. 10 sec.
8)
If this is not the case, adjust P 6, to obtain a release time of approximately 10 sec.
(071221)