ADJUSTMENT OF THE RELEASE CONTROL:

1)

Set the METER switch in position compression.


2)

Set the attack/release SELECT switch in position manual.


3)

Apply a signal of 1 kHz, 0,0 dBU into the input of the compressor.


4)

Adjust the THRESHOLD-control to a reading of -10 VU of the VU-meter


5)

Set the ATTACK-control at fast.


6)

Set the RELEASE-control at slow.


7)

Switch off the 1 kHz and observe that the VU meter moves to 0 VU in approx. 10 sec.


8)

If this is not the case, adjust P 6, to obtain a release time of approximately 10 sec.

































(071221)