beautypg.com

Tube Tech CM1A Comp User Manual

Page 6

background image

LYDKRAFT ApS

Mose Allé 20, DK 2610 Rødovre

Denmark

6

ADJUSTMENT OF THE LED DISPLAY READING "VU":

1)

Switch the METER-selector to Output.


2)

Apply a signal of 1 kHz, 0,0 dBU into the input of the compressor.


3)

Adjust the GAIN-control to an output-reading of +4,0 dBU.


4)

Adjust P10 to a LED display reading of 0 VU.

The -1 LED shall just turn off and the 0 LED shall just turn on.



ADJUSTMENT OF THE LED DISPLAY READING "COMPRESSION":

1)

Turn the THRESHOLD-control fully counter-clockwise.


2)

Switch the METER-selector to Comp.


3)

Set the RATIO-control at 2:1


4)

Apply a signal of 1 kHz, 0,0 dBU into the input of the compressor.


5)

Adjust the GAIN-control to an output-reading of 0,0 dBU.


6)

Adjust P 9 until the LED display is reading 0 VU.

The -1 LED shall just turn off and the 0 LED shall just turn on.


7)

Apply a DC-voltage of +250,0 mV into the side chain jack socket and observe that the
output level has dropped to -10,0 dBU. If this is not the case, adjust the compression
tracking (see above)


8)

Adjust P 8 until the LED display is reading -10,0 VU.

The -20 LED shall just turn off and the -10 LED shall just turn on.


9)

Remove the DC-voltage from the side chain jack socket.


10)

Repeat step 6 - 9.













(130920)