TFC Group STTR/F User Manual
Page 17

Testing the RF transmission range
1. Ensure the receiver is correctly wired to the
output, and that it has a mains supply
(indicated by a continuous red LED at the
receiver)
2. The transmitter display shows the current
actual temperature. Press the UP button until
the set temperature is higher than the actual
temperature.
3. After a few seconds the heater/cooler on icon is
shown – it appears as a rotating symbol above
the P number.
4. Check the green LED on the receiver. It should
be On.
5. If the LED is not On, move the Transmitter
closer to the Receiver.
6. Press the DOWN button to reduce the set
temperature below the current temperature to
turn off the demand from the receiver. The
rotating symbol will disappear, and the green
LED will go Off.
TEMPORARY OVERRIDE
Override between comfort and economic modes
1. During normal operating mode, press the
COMF/ECON button to toggle the current set
temperature to comfort or economic mode.
The HAND symbol will show with the COMF or
ECON symbol.
2. The temporary override will self-reset with the
next programmed change of temperature.
Alternatively press the COMF/ECON button to
revert to automatic operating mode