Appendix A : SPECIFICATIONS
Instrument
Operating Temperature Range
14°F to +122°F (-10°C to +50°C)
Battery
1.5V AA size (3)
Battery Life
> 6 Hours
Fuels
Natural Gas, LPG, Light Oil, Heavy Oil
OPT 1 (Bituminous Coal), OPT 2
(Anthracite Coal), OPT 3 (Coke), OPT 4
(Butane), OPT 5 (Wood), OPT 6
(Bagasse)
Display
Backlit LCD
Data Storage
50 sets of readings
Time & Date
24 Hour Real Time Clock
Dimensions
200mm x 90mm x 60mm
Weight
500g
Casing
Rubber Boot as Standard
Switch Off
Failsafe
Exhaust
Safety Spigot
Conforms to
BS7927 (and the draft BS7967)
Flue Temperature Probe
Construction
Pistol Grip with Stainless Steel Shaft
Hose Length
2500mm
Insertion Length
200mm
'K' Type Thermocouple Accuracy
+/- 0.3%, +/- 1°C
Maximum Temperature
800°C
Gases
Range
Resolution
Accuracy
Oxygen
0-25%
0.1%
+/- 0.3%
Carbon Monoxide
0-10,000 ppm
1 ppm
+/- 5 ppm or 5%
Whichever is greater
Carbon Dioxide
0-25%
0.1%
Calculated
CO/CO2 Ratio
0-0.999
0.001
Calculated
Combustion Efficiency
0-100%
0.1%
Calculated
PRINTING DATA (Continued)
Printout Interpretation
Data from combustion
test is printed here.
Smoke Test Result. For
use on oil fired equip-
ment.
(Circle one to indicate
the result of a smoke
test performed using
the optional A788
smoke test pump.)
Date and time of
combustion test.
Fuel type selected
during test.
Customer information
and signed confirmation
of test.
(Fill in this data and
have the customer sign
for confirmation.)