beautypg.com

Specifications, A. dcv, B2. acv – Test Products International 293 User Manual

Page 8: Product applications

background image

9

3. Specifications

IEC 1010 Over Voltage:
CAT II - 1000V
CAT III - 600V
Pollution Degree 2

a. DCV

Range

Resolution

Accuracy

Impedance

40V

0.01V

±0.75% of reading,

10M

400V

0.1V

±3 digits

600V

1V

b1. ACV (45Hz to 60Hz)

Range

Resolution

Accuracy

Impedance

40V

0.01V

±1.0% of reading,

10M

400V

0.1V

±3 digits

600V

1V

b2. ACV

(20Hz to 45Hz, 60Hz to 1KHz)

Range

Resolution

Accuracy

Impedance

40V

0.01V

±2.5% of reading,

10M

400V

0.1V

±3 digits

600V

1V

UL 3111-1

8

2. Product Applications

Perform the following tests and/or measurements with
the 293 and the appropriate function:

HVAC/R
ACA

• Heat anticipator current in thermostats.

ACV

• Line voltage.

ACV or DCV • Control circuit voltage.
OHMS

• Heating element resistance (continuity).

OHMS

• Compressor winding resistance.

OHMS

• Contactor and relay coil resistance.

ACA

• Motor and compressor start up current.

OHMS

• Continuity of wiring.

Hz/FREQ

• Frequency on control and line voltages.

REC

• Record min/max voltage of controls

and line voltages.

ALL

• Bar graph to indicate rapid fluctuations.

ELECTRICAL
ACV

• Measure line voltage.

ACA

• Measure line current.

OHMS

• Continuity of circuit breakers.

DCV

• Voltage of direct drive DC motors.

ACA

• Start up current of motors, relays,

contactors and transformers.

ELECTRONIC
ACV

• Measure power supply voltage.

ACA

• Measure power supply current.

OHMS

• Continuity of circuit breakers and fuses.

*Warning: Test Leads. Use only correct type and

overvoltage category rating.

!