Operation – Dimplex DWF1146GP User Manual
Page 8
8
www.dimplex.com
Figure 10
Front View
Bottom View
Control Location
A
B
C
Operation
ON
Button
Battery
Cover
OFF
Button
Battery
Figure 11
The controls are located on the bottom surface of the
Sahara fireplace on the right side (Figure 10).
A. Main On/Off Switch
The switch has two On positions marked with and
“Manual”.
The “Manual” position is for manual operation. In this
position the built-in remote control is by-passed.
The position is for operating the unit with the
provided remote control.
When in position the unit is operated with the ON
and OFF buttons of the remote control.
When the switch is in the center position the unit is off.
B. Heater On/Off Switch
The heater On/Off Switch supplies power to the
heater fan and the heater element. When the switch is
in the On position the heater operates if the thermostat
calls for heat.
C. Heater Thermostat Control
To adjust the temperature to your individual
requirements, turn the thermostat control clockwise
all the way to turn on the heater. When the room
reaches the desired temperature, turn the thermostat
knob counter clockwise until you hear a click. Leave in
this position to maintain the room temperature at this
setting. For additional heat, turn clockwise until you
hear the click again and the heater will turn on.
Resetting The Temperature Cutoff Switch
Should the heater overheat, an automatic cut out will
turn the heater off and it will not come back on without
being reset. It can be reset by switching the Main On/
Off Switch to Off and waiting five (5) minutes before
switching the unit back on.
CAUTION: If you need to continuously reset the
heater, unplug the unit and call Dimplex customer
service at 1-888-DIMPLEX (1-888-346-7539).
Remote Operation
The fireplace is supplied with an integrated on/off
remote control.
!
NOTE: Ensure that the fireplace Main On/Off
Switch is set to the Remote Control setting (up
position).
To operate, push the ON button to turn fireplace on,
push the OFF button to turn the fireplace off.
Initialization/Reprogramming
Follow these steps for remote control initialization if
required:
①
Set the main power switch to OFF.
②
Wait a minimum of five (5) seconds and set the 3
Position Switch to the Remote position (refer to
Operation Section).
③
Within 10 seconds of re-acquiring power, press
the ON button located on the remote control
transmitter.
!
NOTE: You will have only 10 seconds to perform
this last step. Failure to do so will result in these
steps needing to be followed again.
This will synchronize the remote control transmitter
and receiver.
Battery Replacement
To replace the battery:
①
Slide battery cover open on the hand held
transmitter (Figure 11).
②
Correctly install one (1) 12 Volt (A23) battery in
the battery holder.
③
Close the battery cover.
Battery must be recycled or disposed of
properly. Check with your Local
Authority or
Retailer for recycling advice in your area.