beautypg.com

Rear panel – StorCase Technology 14-Bay 3U Fibre User Manual

Page 14

background image

Introduction

5

InfoStation 14-Bay FC User's Guide - Rev. A00

StorCase Technology, Inc.

Rear Panel

(Figure 3)

WARNING:

DO NOT USE MODULE HANDLES TO LIFT CHASSIS! These handles are

specifically designed for the installation and removal of modules only!

NOTE:

Blank plate (provided) must be installed if any module slot is left empty. Instal-

lation of the blank plate is necessary for proper cooling inside chassis.

• Port Bypass Module "A" (Figure 4) - InfoStation comes equipped with one (1) Port

Bypass (PBP) Module, for dual FC loop configurability.

• Port Bypass Module "B" Option - Allows the installation of an optional PBP Module,

for quad loop configurability. Refer to Appendix B for further information.

• Power Supply Modules - Two (2) 460W redundant, hot swappable power supply

modules. Each module features overvoltage and overcurrent protection, total usage

hours, and power supply fault detection.

Module LED(s) -

Green LED -

Steady glow indicates normal power supply operation.

No glow indicates no A/C power or abnormal DC voltage range.

Red LED -

Flashing indicates temperature or over/undervoltage condi-

tions.

Power Switch(es) - Rocker switch(es) control power to the power supply module(s).

A/C Power In - Accepts U.S. and other available international standard power cords.

• Fan Modules - Two (2) redundant, hot swappable fan modules. Each module contains

two (2) high-pressure, variable-speed fans for ample chassis cooling (160 CFM each).