Figure 8: receiving frame mounting holes – StorCase Technology DE300i-SWC160 User Manual
Page 18

DE300i-SWC160 User's Guide - Rev. B00
StorCase Technology, Inc.
Installation
11
Mounting
Holes
(Right)
0520
Mounting
Holes
(Bottom)
Front of Unit
Figure 8: Receiving Frame Mounting Holes
5.
Adjust the front of the receiving frame so the carrier slides freely in and out on
the receiving frame guides. The position of adjoining peripheral units may require
adjustment.
6.
To connect a drive to a Remote Activity LED in the computer system or expansion
chassis, connect the appropriate cable(s) to the receiving frame motherboard
as shown in Figure 5. Connect J3A, J3B, and J3C Pins 11 & 12 to a remote activity
LED.
7.
Connect the I/O cables from the host adapter to the receiving frame. The Pin 1
indicator on the cable must be properly aligned. Refer to Figure 5 for the correct
Pin 1 location.
NOTE:
No onboard termination is provided on the DE300i-SWC160.
External termination must be provided.
4.
With the drive carriers locked into place inside the receiving frame, install the
DE300i-SWC160 receiving frame into the drive opening in the computer or
expansion chassis. Use the appropriate guides to position the DE300i-SWC160,
and fasten it into place with the four (4) #6-32 x 1/4 screws provided. Figure
8 illustrates the location of the mounting holes. Mounting holes are provided on
each side and the bottom of the receiving frame to accommodate a variety of
mounting configurations. Use the mounting holes which best suit the computer
or expansion chassis configuration.