Extent of delivery, Storage, Technical description – REFCO DIGIMON User Manual
Page 2

2
HVAC/R
Service Products
REFCO Manufacturing Ltd.
Telefon +41 41 919 72 82
Industriestrasse 11
Telefax +41 41 919 72 83
CH-6285 Hitzkirch (Switzerland)
[email protected] www.refco.ch
Safety glasses and gloves must be worn during the use of the mani-
fold.
REFCO-products are designed and manufactured for use by techni-
cally trained air conditioning and refrigeration service engineers only.
Due to the high pressures employed and the danger due to the physi-
cal and chemical nature of refrigerants and oils used in the systems,
incorrect application could result in accidents, injuries or death.
Extent of delivery
Details about the variations and contents of the DIGIMON manifold are de-
scribed in the REFCO catalog / flyer.
Storage
DIGIMON is a precision measuring instrument. After use store the manifold
in a protected environment. Do not store the manifold with refrigerant in
the unit or hoses.
Technical description
DIGIMON can be used with the following refrigerants:
R11, R113, R114, R12, R123, R124, R13, R134a, R13B1, R22, R227, R23, R290,
R401A(Liq), R401A(Vap), R401B(Liq), R401B(Vap), R402A(Liq), R402A(Vap),
R402B(Liq), R402B(Vap), R403B(Liq), R403B(Vap), R404A, R406A (Liq),
R406A(Vap), R407A(Liq), R407A(Vap), R407C(Liq), R407C(Vap), R408A(Liq),
R408A(Vap), R409A(Liq), R409A(Vap), R410A, R413A(Liq), R413A(Vap),
R414B(Liq), R414B(Vap), R416A, R417A(Liq), R417A(Vap), R420A,
R422A(Liq), R422A(Vap), R422B(Liq), R422B(Vap), R422C(Liq), R422C(Vap),
R422D(Liq), R422D(Vap), R427A(Liq), R427A(Vap), R437A, R500, R502, R503,
R507, R508A, R508B, R744
Liq = Liquid, Vap = Vapor
Maximum working pressure:
Low side
435psi / 30bar / 3000kPa / 3MPa
High side
870psi / 60bar / 6000kPa / 6MPa
Pressure resolution:
0.5psi / 0.01bar / 1kPa / 0.001MPa
Pressure units:
psi / bar / kPa / MPa
Indication positive pressure:
4.35psi to 870psi, 0.3bar to 60bar,
30kPa to 6000kPa, 0.03MPa to 6MPa
Indication negative pressure:
0 to -13,7psi, 0 to -0.95bar,
0 to -95kPa, 0 to -0.095MPa.
Accuracy:
Class 1.0
External K-type thermocouple:
Temperature range:
-40°F to +257°F / -40°C to +125°C