Power supply, Inputs – Datalogic Scanning SH2347 User Manual
Page 2
Power Supply
Power can be supplied to the scanner through the pins provided on the
25-pin connector used for communication with the host.
The power must be between 10 and 30 Vdc only.
13/9
25
1
VS
GND
CHASSIS
USER INTERFACE
GND
V+ (10 - 30 Vdc)
SCANNER
Inputs
The yellow LED is on when the External Trigger forces a current flow
through the EXT TRIG+ and EXT TRIG- pins.
This input is optocoupled and can be driven by both an NPN or PNP type
command. The connections are indicated in the following diagrams:
EXT TRIG+
18
19
+ 5V
SCANNER
EXTERNAL TRIGGER
Signal
V
30 Vdc max.
Vext
EXT TRIG-
Figure 2 - Input NPN command using external power
EXTERNAL TRIGGER
SCANNER
Signal
18
19
+ 5V
VS
9
25
GND
Ground
V
EXT TRIG+
EXT TRIG-
Figure 3 - Input NPN command using scanner power
18
19
+ 5V
SCANNER
EXTERNAL TRIGGER
30 Vdc max.
Vext
V
Signal
Ground
EXT TRIG+
EXT TRIG-
Figure 4 - Input PNP command using external power
EXTERNAL TRIGGER
SCANNER
18
19
+ 5V
VS
9
25
GND
Ground
V
Signal
EXT TRIG+
EXT TRIG-
Figure 5 - Input PNP command using scanner power
For DS1100, the general purpose input IN1 is used in the Standard
Application Program to store the code verifier (see “Store Verifier HW” in the
WinHost Help On Line). Use the input connections indicated in the figure
below. For DS2200, this input is not used.
13/9
17
VS
IN1 -
22
I/O REF
USER INTERFACE
Ground
V
SCANNER
47 K
Figure 6 - IN1 - Input command