OPTI-UPS TS1000B User Manual
Page 2
![background image](/manuals/740042/2/background.png)
Specifications
Model
TS 400
TS 500(B)
TS 650(B)
TS 1000(B)
Maximum Capacity
240W
300W
360W
480W
Topology
Line-interactive
On-battery Output Waveform
Simulated Sine Wave
Input Voltage Range
110/120V or 220/230/240V +/- 25%
Input Frequency
50Hz/60Hz Auto Sensing
Output Voltage Regulation
Rated voltage +/- 5%
Communication
RS232
*)
or USB
*)
Data Line Surge Protection
RJ11/RJ45
*)
Surge Energy Rating
480 Joules
Recharge Time to 90%
< 4 hours
Operating Temperature
0~40°C / 32~104℉
Storage Temperature
-20~60°C / -4~140℉
Relative Humidity
0 to 95% maximum, non-condensing
Audible Noise
<40 dBA
Unit Dimensions (L×W×H), mm
260Ч97Ч135
320Ч97Ч135
Net Weight, kg
4.2
6.0 (6.3)
6.2 (6.5)
6.3 (6.7)
EMC/RFI Compatibility
CE
Safety Certifications
CE, UL, cUL
*)
TS-B models only
Warranty
LIMITED WARRANTY
What the warranty covers:
We guarantee this product to be free from defects in material and
workmanship during the warranty period. If a product proves to be defective
in material or workmanship during the warranty period, we will at our sole
option, repair or replace the product with a like product.
How long the warranty is effective:
For accurate warranty period and conditions, please contact the local branch
offices or your dealers.
Who the warranty protects:
This warranty is valid only for the first consumer purchaser.
What the warranty does not cover:
1. Any product on which the serial number has been defaced, modified
or removed.
2. Damage, deterioration or malfunction resulting from:
a) Accident, misuse, neglect, fire, water, or other acts of nature,
unauthorized product modification, or failure to follow
instructions supplied with the product.
b) Repair or attempted repair by anyone not authorized by
OPTI-UPS.
c) The fault is the result of accidental damage or damage in transit
or transportation, including but not limited to liquid spillage.
d) Removal or installation of the product.
e) Causes external to the product.
f) Use of supplies or parts not meeting our specifications.
g) Normal wear and tear.
h) Any other cause which does not relate to a product defect.
3.
Removal, installation and set-up service charges.
Limitation of implied warranties:
There are no warranties, expressed or implied, which extend beyond the
description contained herein including the implied warranty of merchantability
and fitness for a particular purpose.
Exclusion of damages:
Our liability is limited to the cost of repair or replacement of the product. We
shall not be liable for:
1. Damage to other property caused by any defects in the product,
damages based upon inconvenience, loss of use of the product, loss
of time, loss of profits, loss of business opportunity, loss of goodwill,
loss of data, loss of software, costs of substitute equipment,
interference with business relationships, claims by third parties, or
other commercial loss, even if advised of the possibility of such
damages.
2. Any other damages, whether incidental, consequential or otherwise.
3. Any claim against the customer by any other party.
Troubleshooting
Problems
Possible Cause
Solution
UPS can’t turn on,
LED does not light
Power switch not pressed
long enough
Press the power switch for more than 1 second
until the UPS turns on
Battery voltage is less
than 10V
Recharge the battery for 6 hours by leaving the
UPS plugged in and the load disconnected from
the UPS.
Load is less than 20W at
battery mode
Disable “No Load Shutdown Function”
PCB failure
Call for service
UPS always at battery
mode
Input power cord is loose
Plug in the power cord firmly
Busted input fuse
Replace the fuse
Input voltage too high or
too low
Check input voltage
PCB failure
Call for service
Back up time too short
Battery is not fully
charged or defective
Recharge the battery for 6 hours. If the problem
is still present, replace the battery.
PCB failure
Call for service
Buzzer continuously
beeping
Overload
Remove some loads
Contact Information
OPTI-UPS USA:
Tel: +1-909-869-5700
Fax: +1-909-869-5730
[email protected]
www.opti-ups.com
OPTI-UPS Australia & New Zealand:
Tel: +64-9-441-6470
Fax: +64-9-441-6490
[email protected]
www.opti-ups.com
OPTI-UPS Europe:
Tel: +31-40-401-50-00
Tel: +31-40-262-80-57
Fax: +31-40-254-60-06
[email protected]
www.opti-ups.com
OPTI-UPS Germany:
Tel: +49-2173-9377670
Tel: +49-2173-9377671
Fax: +49-2173-9377672
[email protected]
www.opti-ups.com
OPTI-UPS Middle East:
Tel: +9714-8819-838
Fax: +9714-8819-938
[email protected]
www.opti-ups.com
OPTI-UPS Japan:
Tel: +81-3-3629-5782
Fax: +81-3-5682-0652
[email protected]
www.opti-ups.com
OPTI-UPS Asia:
Tel: +886-2-2246-7272
Fax: +886-2-2246-7312
[email protected]
www.opti-ups.com
Battery replacement procedure
Note: Follow this procedure for safe replacement of the battery. However,
small sparks may occur during the process. This is normal.
1. Turn off the UPS
2. Remove all plugs
3. Remove the four screws from the side slots
4. Gently remove the top cover
5. Disconnect the two wires connecting the battery to the UPS and pull
out the battery
6. Push the new battery into place
7. Connect the wires to the new battery, making sure that the red wire is
connected to the red battery terminal and the black wire to the black
battery terminal
8. Mount the cover and replace the screws
9. Follow the UPS turn on procedure