22

Step 3

Lay the measured length of low voltage wire in a trench following a path from
the selected electrical outlet to the control box. Wires coming up from the
ground should be run through PVC conduit to protect them from lawn mower
blades, weed eaters, and grazing animals. Be sure to bury the wire laid in the
trench.

Step 4

Feed the low voltage wires upward through the strain relief opening on the
lower left of the control box. Pull 6" to 8" of wire into the control box and
tighten the strain relief screw to secure the wires.

IMPORTANT INFORMATION ABOUT LOW VOLTAGE WIRE

The only wire acceptable for use with GTO products is 16 gauge multi-stranded, low voltage, PVC

sheathed wire. This particular gauge enables the transformer to provide an adequate charge through the

control board to the battery at distances up to 1000 ft.

DO NOT

use telephone wire or solid core wire. Unlike multi-stranded wire, these types of wire are

inadequate for use with your gate opener system. Telephone wire and solid core wire do not deliver

enough voltage for your gate opener to function and will cause the system to go into a condition known

as "low voltage lockout."

NEVER

splice wires together. Splicing permits corrosion and seriously degrades the wire's ability to

carry an adequate current.

Step 5

Strip

3

/

16

" off the ends of the low voltage wire

and twist tightly. Attach these ends to the 18VAC
terminals located on the POWER IN terminal block
(see illustration at right). Be certain not to let the
exposed wires touch each other!

Insert one transformer wire into an 18VAC terminal.
Insert the other transformer wire into the remaining
18VAC terminal. The transformer wires can be
connected to the 18VAC terminals regardless of color.

Tighten set screws against exposed end of wires. A
dab of household petroleum jelly on each terminal will
help prevent corrosion.

RED
BLACK

RED
BLACK

Low Voltage Wire

from AC Transformer

18V
AC

SWITCH

SOLAR

RELA

Y OUT

SLA
VE INPUTS

GRN

WHT

BL

UE

BRN

ORG

RED

BLK

NC
RL

Y-COM

NO

MASTER INPUTS

GRN

WHT

BL

UE

BRN

ORG

RED

BLK

+

~

~

Low Voltage Wire

from Transformer

Power Cable from

Opener Arm

PVC Pipe

WARNING! DO NOT PLUG THE TRANSFORMER
INTO AN OUTLET DURING THIS STEP! THE
TRANSFORMER MUST ONLY BE PLUGGED INTO
AN OUTLET DURING STEP 7!