Dacor Preference and Millennia RSE30 User Manual
Page 7
Re-installing the Oven door
Grasp the oven door on opposite sides and
lift it until the door hinges are aligned with the
openings in the oven frame. Holding the door at
about a 30˚ angle from the horizontal, slide the
hinges into the openings until the bottom hinge
arms drop fully into the hinge receptacles. Lower
the door to the fully opened position, and then
rotate the two hinge catches toward the oven.
Open and close the door completely to ensure
that it is properly installed. Peel off the protective
layer of plastic that covers the door panel.
Verifying Proper Gas Operation of
the dual Fuel Ranges (RSd)
wARNINGS:
1. The range and shut-off
valve must be disconnected
from the gas supply piping
during any pressure testing
exceeding 1/2 psi (3.5kPa).
2. The range must be isolated
from the gas supply piping
by closing the shut-off valve
during any pressure testing at
or below 1/2 psi (3.5 kPa).
Before beginning the test procedure, ensure
that all cooktop section control valves are in
the “OFF” position, and all burner rings, burner
caps, and grates are properly positioned on the
top frame. Turn on the gas supply at the shut-off
valve.
Turn on the power supply to the range. Set the
time of day by pressing the “CLOCK” key and
then pressing either of the “TIME•TEMP” keys
(“+” or “-” keys) to advance or reduce the time in
the display in the desired setting.
Test each top burner separately by pressing
and turning one control knob at a time
counterclockwise to the “HIGH” position. All
ignitors will spark continuously, but only the
burner with gas flowing to it will ignite. It will take
approximately 4 seconds for ignition to occur,
at which time the ignitors will stop sparking. If
ignition does not occur within 4 seconds, turn
off the knob, wait for at least 2 minutes to allow
any gas to dissipate, then repeat this ignition
test. The control knob can then be rotated,
counterclockwise, from “HIGH” to “LOW” to
adjust the flame height (size) progressively.
Repeat the ignition test for all top burners.
When installed properly, the flame will be steady
and quiet. It will also have a sharp, blue inner
cone that will vary in length proportional to the
Verify Proper Operation for Electric
Ranges (RSE and MRES)
For RSE range top, rotate one surface element
knob at a time, counterclockwise, to the “HI”
position. Within 5 seconds, the element should
be fully energized and glowing red. Verify that
the residual heat indicator light comes on in
conjunction with the proper element, within
approximately 30 seconds. Return the knob
to the “OFF” position. Repeat for all surface
elements. (Note: The right front element is a
dual coil element. Clockwise rotation from
“LO” to “HI” will energize the inner coil only.
Counterclockwise rotation from “LO” to “HI”
will energize both the inner and outer coils
together).
For MRES range top, turn an element, tap the
“ON/OFF” key then tap the slew up/down area
of the desired element. The element will come
on at a setting of the number touched and may
be adjusted up or down by slewing up or down
on the appropriate key area with your finger.
To activate the Dual Outer Element, tap the
circle key at the end of the slew area (second
row), then tap or slew your finger up or down
on the second row of numbers. The outer ring
element will come on at a setting of the number
touched last. To turn the element off, tap the
“ON/OFF” key. You may turn off all active
elements at the same time by tapping twice on
the “CANCEL•SECURE” key located below the
controls
NOTE:
when the MRES unit is powered
on for the first time, the cooktop
control will go through a self-
check routine. when the self-
check is complete, the cooktop
control will go to SECURE mode.
See Use and Care Manual for
Secure Mode instructions.
Within 5 seconds, the element should be
fully energized and glowing red. Verify that
the residual heat indicator light comes on in
conjunction with the proper element, within
approximately 30 seconds.
RSd dual-Fuel Range Control knob
RSE Range Control knob
MRES “SLEw UP/dOwN” Range Control
NOTES:
If either the oven or cooktop does
not operate properly, follow these
troubleshooting steps:
1. Verify that power (all ranges)
and gas (RSd) are supplied to
the range.
2. Check the electrical
connections (all ranges) and
gas (RSd) supply to ensure
that the installation has been
completed correctly.
3. Repeat the above burner
ignition test (RSd).
4. If the appliance still does
not work, contact an
authorized dACOR service
company at (800) 772-7778.
do not attempt to repair the
appliance yourself. dACOR
is not responsible for service
required to correct a faulty
installation.
CANCEL • SECURE
ON/OFF
ON/OFF
ON/OFF
ON/OFF
NOTE:
Prior to operating the cooktop or
oven sections of the range, please
read the accompanying Use and
Care Manual carefully. Important
safety, service and warranty
information is contained within
this manual.