2 counting pieces without known sample unit weight, 2 select a pre-stored unit weight, 3 high/low check weighing with counting – LW Measurements DCT50 User Manual
Page 18

Final Rev 2013.12.20 18
4.2.1.2 Counting pieces without known sample unit weight
-
Turn scale on
- Wait for "0" to appear on the display.
-
If necessary, press ZERO key to set the display to “0”
- Press SCALE/SELECT key to select SCALE 2, press ENTER to confirm
-Put a pre-known number of samples onto SCALE 2, key-in the known number using the numeric
keypad.
- Press SAMPLE to get the sample unit weight
- Press the SCALE/SELECT key to select either SCALE 1 or SCALE 3, be sure to place the
additional pieces on the scale that is selected, it will display the total number of items.
***NOTE: The items being weighed should be within the selected scales capacity.
4.2.2 Select a pre-stored unit weight
Key in the number of the pre-stored weight (01-16) using the numeric key pad, press MEM/READ key
and select the pre-stored sample unit weight, press ENTER to confirm.
4.2.3 High/Low Check Weighing with Counting
-
Turn scale on
- Wait for "0" to appear on the display.
- If necessary, pre
ss ZERO key to set the display to “0”
- Press QTY/SET key, display will show CH=OFF or CH=ON
-
Press the ENTER key to select “ON”
-
Press [*] key, display will show a flashing “0” at UNIT WEIGHT, key in the lower limit using the
numeric key pad, press [*] g
ain, display will show a flashing “0” at TOTAL, key in the upper limit
using the numeric keypad.
-Press QTY/SET key to confirm the setting and return to weighing mode.
- Press the SCALE/SELECT key to select either SCALE 1 or SCALE 3, be sure to place the
additional pieces on the scale that is selected.
***NOTE: When adding items onto the scale, the scale will beep in a particular tone if the weight
(number of items) is less than the lower limit and beep in another tone if it is higher than the
upper limit.