2 program options – LW Measurements DCT50 User Manual
Page 17

Final Rev 2013.12.20 17
12. UNIT WEIGHT is used when setting the known unit weight data into the scale during normal
operation. (1/1000kg or 1/1000lb)
13. QTY/SET key is used when wanting to switch between the pieces counting function and quantity
check weighing function.
14. NUMERIC (0-9) keys are used for setting numeric data for sample numbers, sample weights or to
set a limit for the HI/LO settings.
15. [*] Key is used to change the division when the scale is in SCALE 3 mode.
16. TOTAL key displays the accumulated total pieces on the scale
17. ESC key is used to exit from the current menu
18. CE key is used for cancelling the numeric setting data or cancels the previous unit weight data.
4.2 Program options
Besides performing accurate simple weighing, your versatile weighing machine can also perform pieces
counting
4.2.1 Pieces counting
4.2.1.1 Counting pieces with known sample unit weight
-
Turn scale on
- Wait for "0" to appear on the display.
- If necessary, press ZERO key to set the display
to “0”
- Key in unit weight, press UNIT WEIGHT key to confirm
-Store the unit weight by pressing MEM/STORE key, display will show a flashing number for
example “01”, this is the location where the stored sample unit weight can be found. Press [*] key
to toggle between 01-16, press the ENTER key to confirm the selection.
- Press the SCALE/SELECT key to select either SCALE 1 or SCALE 3, be sure to place the
additional pieces on the scale that is selected.
***NOTE: The items being weighed should be within the selected scales capacity.