Simply connected, Preparing for installation, Ams-1208p installation – Luxul AMS-1208P User Manual
Page 5: System requirements, Before connecting to the network, Installing the ams-1208p in a rack

Simply Connected
© 2015 Luxul. All Rights Reserved.
Other trademarks and registered trademarks are the property of their respective owners
5
PoE
On
Connected device is receiving PoE Power.
Off
Connected device is not receiving PoE power.
Green
Power being supplied within PD Specified limits
Amber
Power exceeds PD Specified limits
Amber
Flashing
PoE Fault( i.e. problem with Ethernet cable or PoE device).
PREPARING FOR INSTALLATION
System Requirements
Ethernet Cables to connect the AMS-1208P to Ethernet enabled devices
Computer equipped with a Web browser. Supported Web browser versions
include Microsoft I.E. 9.0, Firefox 3.6, Safari 5.0, Chrome 6.0, Opera 10.6 and up.
The Web browser is used to configure the AMS-1208P.
Power must be AC 100-240V 1.6A 50/60Hz.
Before Connecting to the Network
The AMS-1208P can be rack-mounted or used as a desktop switch. Before connect-
ing to the network, please be aware of the following requirements:
Install the AMS-1208P in a stable/safe place to avoid any possible damage
Make sure there is space around the AMS-1208P for adequate ventilation and proper
heat dissipation. It is recommended to have at least 4-6 inches around all sides.
Power outlets should be within 5 feet of the AMS-1208P.
Verify the ground connection of the outlet is functioning properly.
Check the power cord to confirm a secure connection.
When installing the AMS-1208P on a flat surface, attach the rubber feet to the
bottom of the device to avoid scratching the surface.
AMS-1208P INSTALLATION
Installing the AMS-1208P in a Rack
The AMS-1208P can easily be installed in a standard 19” rack. The AMS-1208P includes
two mounting ears for installing and stabilizing the switch. For attaching the mounting
ears and installing the switch within a rack, please refer to the following illustration: