EMERGENCY ENGINE START

1. Remove the top engine cover.

2. Remove the starter cover by unscrewing the bolts.

3. Make sure the engine is in neutral and that the switch is attached to the engine shut off switch.

4. Insert the knotted end of the emergency starter rope in the notch into the flywheel rotor and wind the rope

several times clockwise.

NOTE: If the rope is too long after winding it around the flywheel, shorten at the handle.

5. Pull the rope slowly until resistance is felt.

6. Give a strong pull out to crank and start the engine. Repeat if necessary.

PROCEDURE FOR SUBMERGED MOTOR

If the outboard motor has been submerged, immediately take it to a LEHR dealer. Some corrosion may

begin almost immediately. If you cannot immediately take the outboard to a dealer, follow the procedures

below in order to minimize engine damage.

1. Wash away mud, salt, seaweed, and debris with fresh water.

2. Remove the spark plug, then face the spark plug hole downward to allow any water, mud, or

contaminants to drain.

3. Drain the engine oil completely.

4. Fill the sump with fresh engine oil.

5. Feed small drops of oil throughout carburetor and spark plug hole while cranking the manual starter or

emergency starter rope.

6. Take the outboard motor to a LEHR dealer as soon as possible.

NOTE: Do not attempt to run the outboard motor until it has been inspected.