beautypg.com

Operation, Know your air compressor, Description of operation – Delta A08590 User Manual

Page 11

background image

11- ENG

A08590

OPERATION

Know Your Air Compressor

READ THIS OWNER’S MANUAL AND SAFETY RULES BEFORE OPERATING

YOUR UNIT. Compare the illustrations with your unit to familiarize yourself with

the location of various controls and adjustments. Save this manual for future

reference.

Description of Operation

Become familiar with these controls before operating the unit.
On/Auto/Off Switch: Turn this

switch ON to provide automatic

power to the pressure switch and

OFF to remove power at the end

of each use.
Pressure Switch: The pressure

switch automatically starts the

motor when the air tank pressure

drops below the factory set

"cut-in" pressure. It stops the

motor when the air tank pressure

reaches the factory set "cut-out"

pressure.
Safety Valve: If the pressure switch does not shut off the air compressor at its

"cut-out" pressure setting, the safety valve will protect against high pressure

by "popping out" at its factory set pressure (slightly higher than the pressure

switch "cut-out" setting).
Outlet Pressure Gauge: The outlet pressure gauge indicates the air pressure

available at the outlet side of the regulator. This pressure is controlled by the

regulator and is always less than or equal to the tank pressure.
Tank Pressure Gauge: The tank pressure gauge indicates the reserve air

pressure in the tank.
Regulator: Controls the air pressure shown on the outlet pressure gauge. Turn

the knob clockwise to increase pressure and counterclockwise to decrease

pressure.
Drain Valve: The drain valve is located at the base of the air

tank and is used to drain condensation at the end of each

use.
Cooling System (not shown): This compressor contains an

advanced design cooling system. At the heart of this cooling

system is an engineered fan. It is perfectly normal for this fan

to blow air through the vent holes in large amounts. You know that the cooling

system is working when air is being expelled.
Air Compressor Pump (not shown): Compresses air into the air tank.

Working air is not available until the compressor has raised the air tank

pressure above that required at the air outlet.

On/Auto/Off

Switch

Tank Pressure

Gauge

Outlet

Pressure

Gauge

Regulator

Safety

Valve

Pressure

Switch

Drain

Valve