Heath Consultants Sure-Lock Distance Pro User Manual
Page 20
![background image](/manuals/737818/20/background.png)
17
functioning in the inductive mode, other conductors in the area may also be
energized. When the transmitter is functioning in this application, it is energizing
the intended conductor but it is also being radiated onto the other conductors
surrounding the transmitter.
link fences, guard rails, railroad tracks, or other utilities in the area of the trans-
a direct mode of connection should be used to energize the conductor and to help
eliminate these interfering conductors.
If signals from another conductor are causing interference during the trace, they
the transmitter directly to the conductor by means of a direct connect assembly
(discussed later) or by means of the coupler clamp. If this is not possible, the
placed on the interfering conductor.
Figure 2-1