11. Technical Data
The Bari C.11, certified in compliance with DIN-EN 13240 : 2005-10/1 : 2008-06
and Art. 15 a B-VG (Austria), can only be operated when the fire box is closed; more
than one device can be connected to the chimney. VKF-No.: 22674;
The following data applies to the chimney characteristics in accordance with EN
13384-1 / 2
Combustion Values
Wood
Briquette
Nominal Thermal Output
6
6
kW
CO content at 13% O2
80
79
mg/m³
Efficiency
13
26
%
CO content at 13% O2
1104
882
mg/m³
Waste Gas Mass Flow Rate
5,5
5,5
g/s
Waste Gas Outlet Temp.
320
320
˚C
Min. Supply Pressure at Nominal Thermal Output
12
12
Pa
Depending on the insulation of the building, the nominal thermal output of 6 kW indi-
cated on 20 - 80 m² (subject to change).
Dimensions:
Height
Width
Depth
Stove
108 / 111,5 / 112 cm
48 cm
48 cm
Fire box
43 cm
28 cm
30 cm
Weight
Steel
Ceramic
Soapstone
141 kg
165 kg
205 kg
144 kg with ceramic
152 kg with soapstone
Heat retaining block
+ 81 kg
Flue pipe diameter:
15 cm
Pipe diameter of Hase ventilation system*
10 cm
Front view
Side view
Top view
Dimensions in cm
* For separate air supply in low-energy houses and insufficient combustion air supply
in the room where the stove is installed
Connection area for the
inst. of Hase air system
below
Stove height: max. 112
Height for top installation: 105
Height for the inst. of Hase air
system: 9
24
Ш 35
6,5
Ш 48
Stove‘s angle of rotation:
180° · Can be stopped in
place and locked right/left in
15° gradients. Observe safety
distances to combustible or
flammable materials!