Accessories, Electrical connections – Datalogic Scanning DS8100A-3002 User Manual
Page 4
DS8100A-3002 QUICK GUIDE
4
Accessories:
NAME Description
Part
Number
PWO-480
Power and Connect System 480W
93ACC1767
FS-1
Frame Shaper (8 pcs)
93ACC1750
FBK-8100
Fast Bracket Kit (2 pcs)
93ACC1130
US-8100
Bracket Kit (10 pcs)
93ACC1140
GFC-80
90 Degree Mirror
93A251020
GFC-800
90 Degree Close Distance Mirror
93A201103
S30 Photocell
Kit
93ACC1782
PH-1
Photocell Kit - PNP
93ACC1791
MEP-543
Photocell Kit - NPN
93ACC1728
OEK-2
Optical Encoder Kit (10 m cable + spring)
93ACC1770
OEK-1
Optical Encoder Kit + 10 m cable
93ACC1600
BTK-8100
Bus Terminator Kit (5 pcs)
93ACC1090
BTK-8500
IP65 Terminator Kit (2 pcs)
93A051286
PLL-8000
Optocoupled PLL device
93ACC1280
CAB-8100
10 wire shielded cable D 9.5 mm – 50 m
93ACC1120
CAB-8101
17-pin scanner/scanner connection cable 1.2 m
93A051020
CAB-8102
17-pin scanner/scanner connection cable 2.5 m
93A051030
CAB-8105
17-pin scanner/scanner connection cable 5 m
93A051040
CAB-8501
IP65 Cable Fam 8K 1,2 m
93A051283
CAB-8502
IP65 Cable Fam 8K 2,5 m
93A051284
CAB-8505
IP65 Cable Fam 8K 5 m
93A051285
Datalogic WebSentinel-005
Supervisor (up to 5 arrays)
93A101014
Datalogic WebSentinel-010
Supervisor (up to 10 arrays)
93A101015
Datalogic WebSentinel-020
Supervisor (up to 20 arrays)
93A101016
Datalogic WebSentinel-032
Supervisor (up to 32 arrays)
93A101017
Datalogic WebSentinel-064
Supervisor (up to 64 arrays)
93A101018
Datalogic WebSentinel-128
Supervisor (up to 128 arrays)
93A101019
Datalogic WebSentinel-256
Supervisor (up to 256 arrays)
93A101020
Electrical Connections:
Two 17-pin connectors provide access to the scanner’s local Lonworks network used for both input and output
connections to build a multi-sided or omni-station system.
17-pin Lonworks Connector Pinout
Pin Name
Function
A1
GND
Supply voltage (negative pin)
A2
VS
Supply voltage 20 to 30 Vdc (positive pin)
Cable shield A - internally connected by
1 CHASSIS
capacitor to chassis
2 n.c.
Not
connected
Cable shield B - internally connected by
3 CHASSIS
capacitor to chassis
4 TXAUX
Transmit data of auxiliary RS232
(referred to SGND)
5
SGND
Signal ground (connected to GND)
6 RXAUX
Receive data of auxiliary RS232
(referred to SGND)
7
VS_I/O
Supply voltage of I/O circuit
8
Lon A+
Lonworks a line (positive pin)
9
Lon A-
Lonworks a line (negative pin)
10
Lon B+
Lonworks b line (positive pin)
11
Lon B-
Lonworks b line (negative pin)
12 SYS_I/O
System
signal
13 SYS_ENC_I/O System
signal
14 Reserved
Internally
connected
15 Ref_I/O
Reference voltage of I/O circuit
A1
A2
1
15
Female - Output
A1
A2
1
15
Male - Input
17-pin Local Lonworks Connectors