Led status troubleshooting, Warranty – Go Power! GPSC-12-10A User Manual
Page 7

Go Power! Smart Charger
Owner’s Manual
7
3. LED Status Troubleshooting
Problem and
Symptoms
Possible Cause
Solution
“Red” LED Blinking
Battery is disconnected
Check the battery
connection
Battery fault
Change battery
LED light off
No AC power delivering
Check input power
connection
Polarity reverse
Change cables to the
correct polarity.
- Check DC fuse, if broken
replace the fuse.
Thermal Shutdown
Make sure ventilation is not
obstructed.
Improve ventilation.
Reduce ambient
temperature.
3.1 Selection of battery types:
Use only Wet Lead Acid batteries or Lead Acid batteries with a bulk setting of 14.3V or
higher. The GP-1210 voltage settings are not adjustable.
Model No
Battery Capacity (Min.)
Battery Capacity (Max.)
GP-1210
12V / 30 Ah
12V / 100 Ah
4. Warranty
We warrant this product against defects in materials and workmanship for a period of 12
months from the date of purchase and will repair or replace any defective Go Power!
Battery Charger when directly returned, postage prepaid, to the manufacturer. This
warranty will be considered void if the unit has suffered any obvious physical damage or
alteration either internally or externally, and does not cover damage arising from
improper use such as plugging the unit into unsuitable power sources, attempting to
operate products with excessive power consumption requirements, reverse polarity, or
use in unsuitable climates.
This is the only warranty and the company makes no other warranties, express or
implied, including warranties of merchantability and fitness for a particular purpose.
Repair or replacement are your sole remedies and shall not be liable for damages,
whether direct, incidental, special or consequential, even though caused by negligence
or other fault.