5.4 Resetting Faults

Any of the inverters protection faults can be re-set by turning the inverter off for
five seconds and then turning the inverter on again. The GPSW1500 can also re-
set any of its protection faults using the optional remote on/off switch to turn the
inverter off and then on again.

5.5 Over voltage indicator

The over voltage indicator indicates that the power inverter has shut itself down
because its input voltage has been over 16.5 VDC for the 12 V and 32.0 VDC for
the 24 V.

5.6 Under voltage indicator

The under voltage indicator indicates that the power inverter has shut itself down
because its input voltage has been lower than 10.0 VDC for the 12 V and 20.0
VDC for the 24 V.

5.7 Over temp indicator

The over temp indicator indicates that the power inverter has shut itself down
because it has become overheated. The power inverter may overheat because it
has been operated at power levels above its rating, or because it has been
installed in a location which does not allow it to dissipate heat properly. The
power inverter will restart automatically once it has cooled off.

5.8 Overload indicator

The overload indicator indicates that the power inverter has shut itself down
because its output circuit has been short circuited or drastically overloaded.
Switch the ON/OFF switch to OFF, correct the fault condition, and then switch
the ON/OFF switch back to ON.

5.9 Configuring switches

The configuring switches are used to configure the AC output of the inverter. In
North
America the output is typically configured to 115 VAC and 60 Hz.

5.10 Remote

If the remote is being used on the GPSW-1500, please refer to the GPSW
remote manual for dip switch settings and operations. When using the GPSW-
600-12 Remote Port option, simply connect the two terminals to turn the inverter
on and disconnect them to turn the inverter off. For example you can wire to a
toggle switch and use the toggle as the remote ON/OFF switch.

6. Operating limits

6.1 Power output

The SW1500 W inverter will operate most AC loads within its power rating.

This manual is related to the following products: