ANY ASSISTANCE ?
ANY ASSISTANCE?
9 Fault Finding
In this section fault codes that are
displayed, which CAN be carried out by
the USER to restore appliance operation
(Corrective action: ...). Other fault codes
MUST be solved by a competent person
only.
i
IMPORTANT:
Like all condensing boilers it will
produce a plume of condensation
from the flue terminal in cool
weather.
This is due to the high efficiency
and hence low flue gas
temperature of the boiler. It is
normal and not a fault indication.
• If after carrying out this basic advice and
your appliance still does not work, leave
it turned off and contact your competent
person.
Fault
code
Possible
causes
Solution
The
boiler
stops
working
Electrical
circuit
interrupted
Check that there is
no power cut and
that the appliance is
correctly connected.
When electrical
power comes back
on, the appliance
automatically
comes back into
service. If the fault
persists, contact
your Installation/
Servicing company
or Glow-worm
Service.
Fault
code
Possible
causes
Solution
Reset
Press the reset
button, then wait
5 secs. Should a
fault be indicated,
a further 2 more
attempts can be
made.
xx
Fault
A fault is indicated
by a flashing,
alternating 'F' and
number. If the fault
persists after 3 reset
attempts, contact
your Installation/
Servicing company
or Glow-worm
Service.
Lack of
water in the
installation
(< 0.5 bars)
Contact your
Installation/
Servicing company
or Glow-worm
Service, to have your
system checked.
Excess
water in the
installation
With central heating
off, open the vent
(bleed screw) on
a radiator to allow
water to escape and
reduce the pressure
in the heating
circuit, or contact
your Installation/
Servicing company
or Glow-worm
Service.