beautypg.com

6、the conversion between transceiver modules – FeiYu Tech FY-605 Data Radio User Manual

Page 4

background image

Feiyu Tech FY-

605 Data radio User’s Manual

GuiLin FeiYu Electronic Technology Co., Ltd http://www.feiyudz.cn E-mail: [email protected]

Page 4

A. Connect FY-605 with the Computer and power, and choose the COM ports.

B. Search the radio, when search it successfully (the software will clew it), then we can read

and write the parameters.

C. To change parameters, you can choose the parameters you want to set, re-read after set it

ok, then you can know whether the parameters is you want.

The default COM and RF baud rate is 19200bps.When the RF baud rate is bigger than the

COM baud rate, it can transmit unlimited data at one time, and when the RF baud rate is

smaller than or was equal to the COM baud rate, may transmit 512 bytes data.

Note:

1. Two modules communicate or more modules, their frequency and RF baud rate should be

the same.

2. Module communicate with User’s Equipment, Their COM parameters should be the same.

The following table is FY-

605’s channel and frequency:

Channel

Frequency

Channel

Frequency

1

430.2000MHZ

9

458.5250MHZ

2

431.4288MHZ

10

459.1250MHZ

3

431.7360MHZ

11

459.5250MHZ

4

430.5072MHZ

12

460.1250MHZ

5

434.6940MHZ

13

460.5250MHZ

6

434.2332MHZ

14

461.1250MHZ

7

433.1580MHZ

15

461.5250MHZ

8

433.9260MHZ

16

462.1250MHZ




6

、The Conversion between transceiver modules

It needs 1 ms time delay after the user’s equipment received the data and then transferred

the send data.