6、the conversion between transceiver modules – FeiYu Tech FY-605 Data Radio User Manual
Page 4

Feiyu Tech FY-
605 Data radio User’s Manual
GuiLin FeiYu Electronic Technology Co., Ltd http://www.feiyudz.cn E-mail: [email protected]
Page 4
A. Connect FY-605 with the Computer and power, and choose the COM ports.
B. Search the radio, when search it successfully (the software will clew it), then we can read
and write the parameters.
C. To change parameters, you can choose the parameters you want to set, re-read after set it
ok, then you can know whether the parameters is you want.
The default COM and RF baud rate is 19200bps.When the RF baud rate is bigger than the
COM baud rate, it can transmit unlimited data at one time, and when the RF baud rate is
smaller than or was equal to the COM baud rate, may transmit 512 bytes data.
Note:
1. Two modules communicate or more modules, their frequency and RF baud rate should be
the same.
2. Module communicate with User’s Equipment, Their COM parameters should be the same.
The following table is FY-
605’s channel and frequency:
Channel
Frequency
Channel
Frequency
1
430.2000MHZ
9
458.5250MHZ
2
431.4288MHZ
10
459.1250MHZ
3
431.7360MHZ
11
459.5250MHZ
4
430.5072MHZ
12
460.1250MHZ
5
434.6940MHZ
13
460.5250MHZ
6
434.2332MHZ
14
461.1250MHZ
7
433.1580MHZ
15
461.5250MHZ
8
433.9260MHZ
16
462.1250MHZ
6
、The Conversion between transceiver modules
It needs 1 ms time delay after the user’s equipment received the data and then transferred
the send data.