OPERATING PROCEDURES

Read all of this manual to become thoroughly familiar with this vehicle. Pay particular attention to all Notices, Cautions, Warnings, and Dangers.

20

The charging (DC) cord is equipped with a polarized connector which fits into a matching recep-

tacle on the vehicle.

If vehicle it to be charged with a non E-Z-GO charger, refer to the instructions supplied with the charger.

UNDERSTANDING THE CHARGER

Plugging the charger into the vehicle’s charger receptacle will lock the vehicle out of operation. When the charger is

plugged into the vehicle’s charger receptacle, the charger will automatically turn on and the charger’s LED and the vehi-

cle receptacle’s LED will start flashing GREEN to indicate the batteries are charging.
Once a minimum battery voltage of 2 volts per cell (Vpc) is reached, the charger’s output current will change from a full

current charge to the trickle rated charging current. The length of charge time will vary by how depleted the batteries

are, the input AC voltage, and/or charger ambient temperatures. The charger’s LED will give a SHORT flash if the

charge is less than 80% and a LONG flash if the charge is greater than 80%. If the charger’s LED is a steady GREEN

the batteries are fully charged and the charger may be unplugged, although not necessary. The charger may be left

plugged in for long periods of time to maintain the batteries charge level.
If a fault occurred anytime during the charging the charger’s LED will quickly flash RED. The specific fault is indicated

by the number of RED flashes that occur, there will be a pause and then the flashes will repeat again. There are several

possible conditions that will generate errors. Some errors will require human intervention to first resolve the problem

and then reset the charger by unplugging the DC cord from the vehicle.
If the AC voltage is interrupted and restored, the charger will turn back on automatically.

LED Operation Codes

SHORT GREEN FLASH = less than 80% charged

LONG GREEN FLASH = more than 80% charged

SOLID GREEN = 100% charged

RED FLASH = fault code

LED Fault Codes

RED FLASH: Light turns on briefly, but does not flash after that - check for valid AC voltage.

ONE RED FLASH: One flash, a pause and then again one flash and a pause - Charge Enable Fault: poor con-

tact in the DC connector or dirty contacts or Battery Temperature Fault: battery temperature is greater than 122°

F (50° C) or less than 14° F (-10° C).

TWO RED FLASHES: Two flashes, a pause and then again two flashes and a pause - Battery Voltage Fault:

Battery pack is less than 48.0 Volts or more than 67.2 Volts. Battery pack is too discharged or over charged for

the charger to work.

THREE RED FLASHES: Three flashes, a pause and then again three flashes and a pause - Battery Charge

Time-out: Charge time exceeded 24 hours. This may indicate a problem with the battery pack or that the charger

output current was severely reduced due to high ambient temperatures.

FOUR RED FLASHES: Four flashes, a pause and then again four flashes and a pause - Battery Fault: Charge

time exceeded. This indicates a problem with the battery pack voltage not reaching the required nominal level

within the maximum time allowed.

SIX RED FLASHES: Six flashes, a pause and then again six flashes and a pause - Charger Fault: An internal

fault has been detected. If this fault is displayed again after unplugging the charger’s DC power cord and plug-

ging it back in, the charger must be taken to a qualified service center.