beautypg.com

Sensor, Span, Calibration point – ENMET EX-5155 User Manual

Page 12

background image

EX-5155-MOS

ENMET Corporation

10


Table 3: Examples of Standard and Non-Standard Calibration Gas

Gas

Range

Alarm 1* Alarm 2* Alarm 3*

Sensor

Part Number

Span

Calibration Gas

Calibration

Point

Gas Type/ Standard

Methyl Chloride

0 – 400
PPM

100 PPM

200 PPM

300 PPM

03015-000

100 PPM
Methyl Chloride

100 PPM
Methyl Chloride

Carbon Monoxide

0 – 400
PPM

35 PPM

50 PPM

100 PPM

03011-000

100 PPM
Carbon Monoxide

100 PPM
Carbon Monoxide

Hydrogen Sulfide

0 – 100
PPM

10 PPM

20 PPM

50 PPM

03015-000

100 PPM
Carbon Monoxide

20 PPM
Hydrogen Sulfide

Hydrogen

0 – 1000
PPM

200 PPM

500 PPM

800 PPM

03016-000

800 PPM Hydrogen

800 PPM Hydrogen

Gas Type/ Non – Standard

Considered Special Calibrations, use for examples only. Consult

ENMET

for specifications and availability.

Ammonia

0 – 300
PPM

150 PPM

300 PPM

300 PPM

03019-000

300 PPM Ammonia

See Addendum
Ammonia Calibration

Freon 134A

0 – 2000
PPM

500 PPM

1000 PPM

1500 PPM

03032-000

2% LEL Methane

1200 PPM Freon 134

Freon 12

0 – 2000
PPM

500 PPM

1000 PPM

1500 PPM

03032-000

300 PPM
Carbon Monoxide

1200 PPM Freon 12

Freon 22

0 – 2000
PPM

500 PPM

1000 PPM

1500 PPM

03032-000

2% LEL Methane

730 PPM Freon 22

Acetone

0 – 2000
PPM

500 PPM

750 PPM

1000 PPM

03016-000

500 PPM Hydrogen

1150 PPM Acetone

Methylene Chloride

0 – 200
PPM

25 PPM

50 PPM

100 PPM

03015-000

100 PPM
Methyl Chloride

140 PPM Methylene
Chloride

*

N

OTE

: