beautypg.com

Elenco Digital Bench Multimeter User Manual

Page 23

background image

DVM645BI GB

22


Capacitance

Range

resolution

Accuracy (% reading + digits)

4nF

1pF

± (2% rdg + 40d) in relative mode

40nF

10pF

± (2% rdg + 5d) in relative mode

400nF

100pF

± (2% rdg + 5d) in relative mode

4µF

1nF

± (0.5% rdg + 5d)

40µF

10nF

± (2% rdg + 5d) at <= 20µF
± (5% rdg + 5d) at > 20µF

Input protection: 250V RMS

Frequency Counter

Ranges: 100Hz, 1kHz, 10kHz, 100kHz, 1MHz
Resolution: 0.01Hz in the 100Hz range
Accuracy: ± (0.1% + 4d)
Sensitivity: 100mV rms for 1Hz to 20kHz, 500mV rms for 20kHz to 1MHz
Input protection: 250V RMS

Adaptive Range

Display: 10 units per 1mV DC
Accuracy: ± (0.3% + 5d)
Input protection: 250V RMS