beautypg.com

Caution, Operation, Piping – EarthQuake WP6530 User Manual

Page 8: Operator's manual, Figure 3, Priming port

background image

Operator's Manual

WP6520 and WP6530 Water Pumps

Check for parts online at

www.getearthquake.com or call 800-345-6007 M-F 8-5

8

OPERATION

1. Fill the engine crankcase with oil. Refer to the engine operat-

ing manual for the specific grade of oil and amount required.

2. Fill the engine fuel tank with gasoline. Refer to the engine

operating manual for specific gasoline type that is most ef-

ficient for this engine.

3. Add water to the priming port on the pump (SEE FIGURE 3).

Continue adding water until the water level is approximately

3 inches from the top. Install the priming plug. The water in

the pump will create the suction that primes the pump.

4. Turn fuel valve to ‘ON’ position.
5. Move choke lever to ‘CHOKE’ position.
6. Move throttle lever to ‘START’ position.
7. Pull engine crank until engine starts. Once engine starts,

move choke lever to ‘RUN’ position.

noTE: The pump may take several minutes to prime.

PIPING

Always place the pump as close as possible to the liquid being

pumped. Keep all pipe and hose lines as short and straight as possible.
All suction connections must be airtight. If the pump won’t

prime, check for leaks in the suction piping or fittings. If flexible

suction hose is used instead of pipe, use reinforced hose with a

two inch inner diameter. Non-reinforced flexible hose may col-

lapse from the vacuum created as the pump primes.
Always use a strainer at the end of the suction pipe or hose. Posi-

tion strainer so it doesn’t become clogged with stones or debris.

A suction line check valve next to strainer is recommended.
Do not use this pump for suction lifts over twenty-five feet.

CAUTION

NEVER STORE ENGINE WITH FUEL IN THE TANk INDOORS.

FUEL AND FUEL VAPORS ARE HIGHLy FLAMMABLE.
AN ADULT MUST ALWAyS HANDLE AND FILL THE EN-

GINE WITH FUEL.
ALWAyS HANDLE FUEL IN A WELL VENTILATED AREA,

OUTDOORS, AWAy FROM FLAMES OR SPARkS.
DO NOT START ENGINE IF FUEL IS SPILLED. WIPE OFF

ExCESS FUEL AND ALLOW TO DRy. REMOVE ENGINE

FROM AREA TO AVOID SPARkS.

CAUTION

DO NOT START yOUR WATER PUMP UNIT UNTIL yOU

HAVE READ THE ENGINE MANUAL THAT CAME WITH

yOUR ENGINE, AND THE "WARNINGS AND SAFETy

PRECAUTIONS" SECTION IN THIS MANUAL. IF yOU

HAVE READ THESE, FOLLOW THE STEPS TO START yOUR

PUMP UNIT.

Figure 3

CAUTION

MAkE SURE THE UNIT IS IN A STABLE POSITION BE-

FORE PULLING THE STARTER HANDLE.
IF ENGINE FAILS TO START AFTER TRyING STARTING

PROCEDURES, PLEASE CONTACT OUR CUSTOMER

SERVICE DEPARTMENT AT 800-345-6007.
STARTER ROPE CAN CAUSE AN UNANTICIPATED JERk

TOWARDS ENGINE. PLEASE FOLLOW INSTRUCTIONS

TO AVOID INJURy.
NEVER LEAVE ENGINE RUNNING WHILE UNATTEND-

ED. TURN OFF AFTER EVERy USE.
NEVER CARRy PUMP FROM ONE LOCATION TO AN-

OTHER WHILE ENGINE IS RUNNING.

A

PARTS TO BE FREE OF

BURRS AND SHARP EDGES

THIS DRAWING AND ALL INFORMATION CONTAINED HEREIN IS AND REMAINS THE PROPERTY

OF ARDISAM INC.

AND IS CONFIDENTIAL. IT IS SUBMITTED AND MAY BE USED ONLY IN CONNECTION WITH

ARDISAMS' PROPOSALS

AND/OR ITS CUSTOMERS' ORDERS. IT SHALL NOT BE DISCLOSED TO OTHERS OR COPIED

WITHOUT ARDISAMS'

SPECIFIC WRITTEN CONSENT AND SHALL BE IMMEDIATELY RETURNED UPON REQUEST.

MATERIAL

NAME

TREATMENT

DR BY

APPD

PRT NO

13001

PT WEIGHT

SURFACE AREA

DATE

REVISION

THIRD ANGLE PROJECTION

SEE BILL OF MATERIALS

NONE

21176

3235032

WP6520 WATERPUMP

3

LAR

7/29/2011

SHEET: 1 OF 1

ALL ANGLES ARE DECIMAL DEGREES

UNLESS OTHERWISE SPECIFIED

DIMENSIONS ARE IN MILLIMETERS

THREADS CLASS 2

0.0 ± 1.0°

0 ± 2°

ANGLES:

0.000 ± 0.250 MM

0.00 ± 0.75 MM

0.0 ± 2.5 MM

OTHERWISE NOTED:

TOLERANCE UNLESS

priming port

This manual is related to the following products: