beautypg.com

Troubleshooting guide – EarthQuake 14268 User Manual

Page 18

background image

Operator's Manual

Viper® 212cc 4-Cycle Engine

18

For more information email

[email protected] or call 800-345-6007 M-F 8-5

TROUBLESHOOTING GUIDE

PROBLEM

POSSIBLE CAUSE

REMEDY/ACTION

Engine will not start

1. Power switch off

1. Flip switch to ON position

2. Fuel switch off

2. Check fuel switch is on

3. Spark plug wire disconnected

3. Connect spark plug wire to spark plug

4. Out of fuel

4. Refuel

5. Spark plug wet, faulty or improperly

gapped

5. Clean, replace or gap spark plug

Electric Start

5. Battery discharged

5. Recharge battery

Engine runs rough, floods during op-

eration

1. Dirty air filter

1. Clean or replace air filter

2. Choke partially engaged

2. Turn off choke

3. Carburetor out of adjustment

3. Call factory

Engine is hard to start

1. Stale fuel

1. Drain old fuel and replace with fresh.

Use fuel stabilizer at end of season

2. Spark plug wire loose

2. Make sure spark wire is securely attached

to spark plug

3. Dirty carburetor

3. Clean carburetor, use fuel stabilizer, new

fuel can

Engine misses or lacks power

1. Clogged fuel tank or fuel filter

1. Remove and clean

2. Clogged air filter

2. Clean or replace

3. Improper carburetor adjustment

3. Call factory

4. Spark plug dirty, improper gap, or

wrong type

4. Replace spark plug and adjust gap to

.030”

Engine runs, then quits

1. Fuel cap not venting

1. Replace fuel cap

Contact Ardisam customer service if above remedies fail.