background image

OPERATING AND MAINTENANCE INSTRUCTIONS

196cc 4-Cycle Engine

Check for parts online at

www.getearthquake.com or call 800-345-6007 M-F 8-5

12

ENGINE OPERATION

REVIEW SECTION “PRE-OPERATION INSPECTION” BEFORE STARTING

ENGINE.

STARTING & STOPPING ENGINE

MANUAL START ENGINE
1. Move engine to a well ventilated area, always outdoors, to prevent

carbon monoxide poisoning.

2. Move to an area away from flames or sparks, to avoid ignition of

vapors if present.

3. Remove all debris from air cleaner holes and gas cap to ensure

proper air flow.

4. Choke:

“Full choke” position is established by moving the choke lever as

far left to the CHOKE position as possible. SEE FIGURE 5.

“Half choke” position is established when the choke lever is

maneuvered half-way between CHOKE and RUN positions. SEE

FIGURE 6.

First Start & Cold Start: Move choke lever to “full choke.” SEE

FIGURE 5.
Warm Start:
“No choke” or “half choke” is needed. SEE FIGURE 7.

WARNING

!

CARBON MONOXIDE GAS IS TOXIC. INHALATION

CAN CAUSE UNCONSCIOUSNESS AND DEATH.
NEVER LEAVE ENGINE RUNNING WHILE UNATTEND-

ED.
DO NOT ATTEMPT TO START ENGINE IN THE FOLLOW-

ING WAYS:
• DO NOT USE STARTING FLUID.
• DO NOT SPRAY FLAMMABLE LIQUIDS OR VAPORS

INTO AIR CLEANER, CARBURETOR OR SPARK PLUG

CHAMBER.

• DO NOT REMOVE SPARK PLUG AND PULL ON

STARTER ROPE. FLAMMABLE FUEL CAN SPRAY

OUT AND IGNITE FROM A SPARK FROM SPARK

PLUG.

CAUTION

!

DO NOT STOP ENGINE BY MOVING CHOKE CONTROL

TO CHOKE. BACKFIRE, ENGINE DAMAGE, OR FIRE

MAY OCCUR.

FIGURE 6

FIGURE 7

FIGURE 5

“FULL CHOKE”

position

“HALF CHOKE”

position

“NO CHOKE”

position

This manual is related to the following products: