800 watt inverter generator, Specifications – EarthQuake MC43ES User Manual
Page 11

Check for parts online at
www.getearthquake.com
or call 800-345-6007 M-F 8-5
11
Operator’s Manual
800 Watt Inverter Generator
Ac Voltage
60Hz -120V
Max Output
800 watts
Rated Output
700 watts
Dc Output
12V / 4.5A
Engine Displacement
40cc
Engine Type
4-cycle
Noise Level (@7M)
58 dB
Fuel Tank Capacity
0.55 gallons (2.1 liters)
Recommended Fuel Type
Minimum 87 octane gasoline
with NO ethanol content
NOTE: If using an ethanol
blended fuel, a fuel
stabilizer, mixed
to manufacturer
specifications, is
recommended.
Run Time (25% Load)
8.2 hours
Oil Tank Capacity
11.8 ounces (.35 liter)
Oil Type
10W-30 (SJ, SL or better)
Spark Plug
CMR6A (TORCH)
Spark Plug Gap
0.6 - 0.7 mm
Weight Of Unit
20 lb
Unit Size L X W X H
(Inches)
15.6 x 8.2 x 14.0
SPECIFICATIONS
Oil Warning System
When the oil level reaches a low level, the engine will stop
automatically. In order to restart the engine, the oil must be
refilled.
NOTE: It is important to check the oil level before each use.
Engine Switch
The engine switch must be in the RUN position to start
and run the generator. Push the engine switch to the STOP
position to stop the generator. SEE FIGURE 1
NOTE: It is recommended to keep the engine switch in the
STOP position while the generator is not in use.
Economy Control Switch
When the economy control switch is in the ON position, the
economy control unit controls the engine speed according to
the connected load. The results are better fuel usage and lower
noise levels. SEE FIGURE 1
NOTE: When starting the generator, and while plugging
in and starting connected devices, make sure the
economy control switch is in the OFF position.
When all units are running smoothly, push the
economy switch to the ON position .
DC Circuit Protector
The DC circuit protector turns off automatically when the load
exceeds the generator’s rated output. SEE FIGURE 1
NOTE: If generator turns off due to access load, reduce
the load to within specific generator rated output
levels.
Fuel Tank Cap Air Vent
The fuel tank cap is provided with an air vent knob to stop fuel
flow. The air vent knob must be turned clockwise to the OPEN
position to run the generator. This will allow for fuel flow in
the engine. When the generator is not in use, turn the air vent
knob counterclockwise to the CLOSED position. This will block
air flow to the fuel tank. SEE FIGURE 2
Fuel Valve
The fuel valve must be in the ON position to run the generator.
When the generator is not in use, turn the fuel valve to the
OFF position. SEE FIGURE 2