beautypg.com

DaySequerra M2A-FM User Manual

Page 8

background image

8

M2A-FM User Manual


All Alarms

• Select “ON” to activate all alarms at the minimum threshold with the minimum alarm

delay. Select “OFF” to set all alarms to off; select “SETUP” option to continue with alarm
configuration menu. Use UP and DN switches to toggle the setting.

Push “SELECT” switch to increment the menu to the next alarm function.


A

L

L

A

L

A

R

M

S

O N O F F > S E T U P <


Alarm Output 1 – RF Carrier Loss (alarm based on analog RF signal strength)

• Highlight desired “SET” or “OFF” option using UP and DN switches to toggle the setting.

Select “SET” to set this alarm and continue with alarm configuration menu; select “OFF”
to set this alarm function to off. Push “SELECT” to continue.


R F C A R R I E R L O S S
>

S

E

T

<

O

F

F

• If “SET” is selected, submenu for “Level” threshold with “LOW”, “MED” and “HIGH”

options is displayed next. “LOW” option sets RF carrier loss threshold for approximately
10µV (25dBf); “MED” option sets RF carrier loss threshold for approximately 100µV
(45dBf); and “HIGH” option sets RF carrier loss threshold for approximately 3KµV
(75dBf). Use UP and DN switches to toggle the setting and highlight the desired option.

R F C A R R I E R L E V E L
L O W > M E D < H I G H


Push “SELECT” switch to increment the menu to the next alarm function.

• Submenu for “Alarm Delay” with “30”, “60”, “120” and “240” second options is displayed

next. Use UP and DN switches to toggle the setting and highlight the desired option.


A L A R M D E L A Y
3 0 > 6 0 < 1 2 0 2 4 0 S


Push “SELECT” switch to increment the menu to the next alarm function.