beautypg.com

Electrical installation – Da-Lite Designer Contour Electrol User Manual

Page 4

background image

4

Electrical Installation

Internal wiring has been completed at the factory. Installer must route power to the wall switch and to the junction box located on the

left end of the screen case.

Standard installation is for a single 120VAC or 240VAC wall switch to control the screen. Optional Control units may have been ordered.

Wiring diagrams for the built-in VPI and low voltage control are included in these instructions. Refer to additional instructions for the
external VPI, external low voltage control, SCB-100 and SCB-200. Refer to the appropriate wiring diagram for your screen.

Up

Up

Off

Off

Down

Down

This Switch Can Not
be used with LVC.

SPDT Switch with
Center Off

Rear or DPDT Switch
with Center Off

120V Wiring Diagram

For Standard

Wall Switch

240V Wiring Diagram

For Standard

Wall Switch

AC (Common)

AC HOT 120VAC 60HZ 1 AMP
Black/Yellow

Black

Black

Red

Whit

e

Black (Do

wn)

R

ed (Up)

Junction Box
Located In Left Endcap

Junction Box
Located In Left Endcap

Ground-Must Be Connected
To Building Ground

White
Black
Red
Green

Motor

NOTE: A single switch cannot be used to operate more

than one screen. Contact the factory for further information.

This Switch Can Not
be used with LVC.

Brown and Yellow AC HOT
220/240 VAC 50HZ 2 AMP.

Blue AC (Common)

Brown

BLUE JUMPER

WIRE

Blue

Br

own (Do

wn)

Black (Up)

Blue
Brown
Black
Green

MOTOR

NOTE: A single switch cannot be used to operate more

than one screen. Contact the factory for further information.

Ground To Case

Ground To Case

Ground-Must Be Connected
To Building Ground