Client and host firmware compatibility, Buttons and indicators, Mandatory setup and cooling requirements – ClearCube CD7600-Series User Manual

Page 2

background image

ClearCube Technology, Inc. 3700 W Parmer Lane Austin, Texas 78727 (512) 652-3500 www.clearcube.com

G0200156 Rev A, 1.0.01.23.2013

Page 2 of 4

• Support for independently-configurable monitors

• PC–over–IP (PCoIP™) Tera2 processors, delivering PC

video, audio, and USB over an IP network

• Integrated smart card reader (on supporting models)

• HD audio in and out (front) and HD audio out (rear)

Client and Host Firmware Compatibility

ClearCube recommends using the same Teradici

firmware

version on PCoIP devices whenever possible.

• CD9600-series and CD7600-series zero clients include

Tera2 processors, requiring Teradici firmware 4.0.3 and
higher.

• If Tera1 devices (that is, any models other than CD9600-

series and CD7600-series) in a deployment connect to
Tera2 devices, the Tera1 devices must use Teradici
firmware version 4.0.2.

• Dual-monitor CD9600-series and CD7600-series zero

clients do not support connection to Tera1 quad devices.

See PC-over-IP System User’s Guide and PCoIP Firmware
Support and Compatibility Guide
on the ClearCube Support
site for instructions about identifying and updating PCoIP
device firmware.

Buttons and Indicators

The list below shows indicators and front panel button
operations:

• Power Button Colors

Green (solid): device is powered on.

Green (blinking): PCoIP session is sleeping. Press

any key on the keyboard to wake the session.

Orange: device is in low-power state and

wake-on-LAN (WoL) or wake-on-USB (WoUSB) is
enabled. ClearCube Sentral or third-party utilities can
provide WoL and WoUSB features for devices.

• Power Button Operations

Power on: when orange, press briefly (turns green)

Power off: press and hold for 3 seconds (turns

orange)

While in session:

when connected to a PCoIP host card, press to

display the Zero Client Control Panel (on monitor)
with options to disconnect or power down host
device. Press the power button repeatedly to scroll
through options or to cancel.

when connected to a VM, press to disconnect.

PCoIP Session Indicator—shows when a connection, or

session, is established between the zero client and a host.
The link indicator displays one of the following:

Green—a session is established between the client

and a host.

Off—there is no session between the client and a host.

• Smart Card Reader (on supporting models only)

Yellow-Green—smart card reader is powered on.

Red—smart card has been reset. When red light is

flashing, the IC Card is reading or writing.

Mandatory Setup and Cooling Requirements

• Ensure at least 4 inches of space around all zero client

edges and at least 2 inches of space above the client.

• Ambient operating temperature: 0° to 35° C

(32° to 95° F).

Dual-Monitor Cloud Desktop Quad-Monitor Cloud Desktop

2 DVI monitors up to

1920 × 1200

4 DVI monitors up to

1920 × 1200

1 DVI monitor up to

2560 × 1600

(requires single-link-DVI-to-dual-

link-DVI Y-cable adapter, included)

2 DVI monitors up to

2560 × 1600

(requires single-link-DVI-to-dual-

link-DVI Y-cable adapter, included)