ALPHA PROFILE 800 “ST”
• FUNCTION - channel: 35
BIT
EFFECT
255
51-62
38-50
0-37
LINEAR (Default)
UNUSED RANGE
UNUSED RANGE
63
CONVENTIONAL
DIMMER CURVE
FUNCTION
The functions are actived passing through unused range and staying 5 seconds in
necessary level.
• TILT FINE - channel 34
Operation with option Invert Tilt
G
Off
(Pan conventionally represented at 0 bit and option Invert Pan
G
Off)
BIT
255
0
Operation with option Invert Tilt
G
On
(Pan conventionally represented at 0 bit and option Invert Pan
G
Off)
• TILT - channel 33
Operation with option Invert Tilt
G
Off
(Pan conventionally represented at 0 bit and option Invert Pan
G
Off)
BIT
255
128
0
Operation with option Invert Tilt
G
On
(Pan conventionally represented at 0 bit and option Invert Pan
G
Off)
BIT
255
128
0
BIT
255
0
• RESET - channel: 36
BIT
EFFECT
255
128
127
77
76
26
25
0
Complete reset is activated passing
throug the unused range and staying
5 seconds in complete reset levels.
COMPLETE RESET
PAN / TILT RESET
PAN / TILT RESET
EFFECTS RESET
EFFECTS RESET
UNUSED RANGE
Pan / Tilt reset is activated passing
throug the unused range and staying
5 seconds in Pan / Tilt reset levels.
Effects reset is activated passing
throug the unused range and staying
5 seconds in Effects reset levels.
COMPLETE RESET
• LAMP CONTROL (only with option LAMP DMX On) - channel: 37
IMPORTANT: Alpha Profile 800 “ST” is not provided with hot restrike igniter
LAMP ON (FULL POWER)
LAMP ON (FULL POWER)
BIT
EFFECT
255
180
0
101
100
LAMP OFF
179
26
LAMP OFF
25
UNUSED RANGE
Lamp ignition after 5 s
in full power levels.
Lamp switch off passing
throug the unused
range and staying 5 s in
Lamp OFF levels.
UNUSED RANGE
UNUSED RANGE
Immediate transition
from half to full power.
ON
ON
OFF
OFF
The functions are actived passing through unused range and staying 5 seconds in
necessary level.
The functions are actived passing through unused range and staying 5 seconds in
necessary level.