Clay Paky GOLDEN FOG User Manual
Page 4

GOLDEN FOG 1000
GOLDEN FOG 2000 and 2000 DMX
8
TECHNICAL DATA
8
Power supply
• 200 - 240V 50/60Hz
Input power
• GOLDEN FOG 1000:
1,000 VA
• GOLDEN FOG 2000:
2,000 VA
• GOLDEN FOG 2000 DMX: 2,000 VA
Tank capacity
• GOLDEN FOG 1000:
1 litre
• GOLDEN FOG 2000 and 2000DMX: 2 litres
Consumption and maximum delivery
• GOLDEN FOG 1000:
27 g/min
• GOLDEN FOG 2000:
55 g/min
• GOLDEN FOG 2000 DMX:
46 g/min
Pre-heating time
• GOLDEN FOG 1000: 5 min.÷ 5 min. 30 sec.
• GOLDEN FOG 2000: 4 min.÷ 4 min. 30 sec.
• GOLDEN FOG
2000 DMX:
4 min.÷ 4 min. 30 sec.
Smoke delivery time
• GOLDEN FOG 1000: continuous
• GOLDEN FOG 2000: 60”/65”
• GOLDEN FOG 2000 DMX: 30 sec. at
100%, continuous with adjustment
CONTROL SYSTEMS
• GOLDEN FOG 1000 - 2000
- Manual control
- Remote manual control
- 0-10V analogue input
• GOLDEN FOG 2000 DMX
- Serial digital input
RS232/423(PMX) or DMX512
- 0-10V analogue input
INDICATORS
• GOLDEN FOG 1000 - 2000
- Machine ready indicator light
on remote control
- Power light
• GOLDEN FOG 2000 DMX
- Power light
- Fluid finished indicator light
- Automatic operation
- DMX signal reception
- PMX signal reception
- Error in receiving signals
SAFETY DEVICES
Power supply automatically cut off in the
event of the boiler overheating.
Weight and dimensions
• GOLDEN FOG 1000:
Weight 7.5 Kg (16 lbs 8 ozs)
• GOLDEN FOG 2000:
Weight 11 Kg (24 lbs 3 ozs)
• GOLDEN FOG 2000 DMX:
Weight 12 Kg (26 lbs 6 ozs)
A mm
270 (10.63”)
310 (12.20”)
B mm
490 (19.29”)
490 (19.29”)
C mm
230 (9.06”)
340 (13.39”)
No mains supply.
Check the supply socket
is powered and/or fuse
conductivity.
Signal transmission cable short-
circuited or disconnected.
Replace cables.
Cannon not properly inserted.
Insert the Cannon on the back
of the machine.
No liquid in tank.
Fill the tank with liquid.
Internal mechanical part broken.
Call an authorized technician.
Tube not inserted properly.
Put the tube back into the tank.
Wrong address.
Check the digital address.
Electronics broken.
Call an authorized technician.
THE LED ON THE REMOTE CONTROL FAILS TO COME ON
THE FITTING WILL NOT SWITCH ON
NO SMOKE IS GENERATED
TROUBLE
THE TUBE FAILS TO DRAW LIQUID
IT FAILS TO WORK WITH DIGITAL SIGNALS
POSSIBLE CAUSES
CHECKS AND REMEDIES
•
•
•
•
•
•
•
•
TROUBLESHOOTING
7
A
B
C