English, Maintenance, Code – Clay Paky GOLDEN FOG User Manual
Page 3: 10 v analogue connection with decoding

SERIAL NUMBER
IF11153
FUSE
5x20
5 A
T
250 V
CODE
C.81005
200V 220V 240V
50 Hz
60 Hz
60 Hz
7
Golden Fog
1 - Channels 01
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
1
2
4
8
16
32
64
128
256
TEST
OFF
ON
OFF
ON
CODE
ON
OFF
ON
OFF
ON
OFF
OFF
ON
Golden Fog
2 - Channels 02
Golden Fog
3 - Channels 03
Golden Fog
4 - Channels 04
Golden Fog
5 - Channels 05
Golden Fog
6 - Channels 06
Golden Fog
7 - Channels 07
Golden Fog
8 - Channels 08
Golden Fog
9 - Channels 09
Golden Fog 10 - Channels 10
Golden Fog 11 - Channels 11
Golden Fog 12 - Channels 12
0-10 V analogue connection with decoding
0-10V
0-10V
0-10V
Is
FOG
1
2
3
4
5
6
7
8
ANALOGUE
INPUTS 0 - 10 V
On the back of the GOLDEN FOG 2000 DMX there is a selector with 6 microswit-
ches (15) that make it possible to control 6 fittings simultaneously on separate
channels, switching over the microswitches according to the following table.
Golden Fog
1
ON
OFF
ON
OFF
ON
OFF
ON
OFF
1
2
3
4
5
6
OFF
ON
OFF
ON
CODE
Golden Fog
2
Golden Fog
4
Golden Fog
3
Golden Fog
5
Golden Fog
6
• Automatic operation
Turning the AUTO microswitch (16) onto ON puts the fitting onto automatic ope-
ration. Keeping the microswitch on this position, the frequency of the sprays of
smoke delivered depends on the level set on the DIL microswitches (14) normal-
ly used to select the address; there are therefore 512 possibilities for adjust-
ment.
If automatic operation is activated, the four LEDs (17) on the rear panel come on
alternately from the bottom upwards.
When the machine is controlled via the control unit (AUTO microswitch on the
OFF position) the frequency of the sprays varies as the adjustment potentiome-
ter moves forward.
After completing all the preliminary operations and installation, fill the tank with
smoke machine liquid, press the switch, wait for the boiler to reach temperature,
then check that smoke is generated and everything works properly.
IMPORTANT: Use solely CLAY PAKY smoke liquid in the light, medium and
heavy versions. Other types of fluid could impair the operation of the smoke ma-
chine and/or seriously damage some components.
On the rear panel of the GOLDEN FOG 2000 DMX model there is an indicator li-
ght (18 – “Fluid Empty”) to signal the liquid has finished.
USE
5
18
AUTO
256
128
64
32
4
16
8
1
2
ST
AR
T ADDRESS SELECT
ON
1
2
3
4
5
6
CHANNEL SELECT
1
4
8
FLUID
EMPTY
DATA
ERROR
PMX
DMX
• Replacing fuses
To replace the fuses, press the tab
(19) and take out the fuse-holder box
(20). Replace blown fuses with new
ones of the type specified on the label
(21) on the fuse-holder box (20).
Put it back in so the tab (19) clicks ho-
me.
• Periodical cleaning
Every time before use, clean any drops
of fluid off the outlet pipe (22).
Approximately every 1000 hours of
operation, have qualified personnel
check the machine.
MAINTENANCE
6
19
20
21
22
ENGLISH