Operating the Unit

Unit Operation

This appliance is not intended for use by young children or infirm persons unless
they have been adequately supervised by a responsible person to ensure that they
can use the appliance safely.

Young children should be supervised to ensure they do not play with the appliance.

Start-Up Sequence

1. Before starting ensure the protective membrane has

been removed from the control decal.

2. Press the ON / OFF button.

3. The heater will start in the Manual mode of operation.

Within 10 seconds the gas valve will open and the
sparker will function. Ignition will commence on a low gas
rate.

4. Within 5 seconds of ignition the flame sensor will prove

the flame.

5. Within 20 seconds the fan will operate on low fan speed.

6. The Gas Valve Level and Fan Speed can be adjusted to

desired point.

7. Alternatively the heater can be set to Automatic mode.

The gas valve will now modulate according to the

sensing of the room thermistor.

Once the heater has reached the set temperature,

the flame will extinguish and the fan will continue to
run for at least one minute.

Once the room temperature drops approximately

2

o

C, the heating sequence will restart.

U

SING THE

C

ONTROLS

The user interface consists of a display, a push button for turning the unit on and off and five touch
buttons. The touch buttons are named SELECT, PROGRAM, MODE, UP and DOWN. There is also
a buzzer that emits a short beep for valid user action and a longer beep for invalid user actions.