AZEL i-Link SERIES ZONE CONTROLS (CIRCULATOR PUMP SWITCHING RELAYS ) FOR HYDRONIC / RADIANT FLOOR HEATING SYSTEMS User Manual
AZEL Relay
A
ZEL
TECHNOLOGIES
SP-82/83/84/85/86
MULTI- ZONE SWITCHING RELAYS
INSTALLATION AND OPERATING INSTRUCTIONS
FEATURES
.
Front panel indicator lights
.
Field selectable priority
.
Priority timer for protection of a priority zone malfunction
and prevention of freeze-ups in the heating zones.
.
Unlimited zone expansion
.
Capable of turning on extra system circulator
.
Addition features for SP-84/85/86: Manual priority
override(bypass) for each of the secondary zone
.
Isolated End Switch and Priority End Switch
.
Compact and modern design
.
Fuse protection
.
Power surge protection
.
Safety design with all electronic components hiding
behind the enclosure
.
Simplified wiring
.
Contractor friendly PCB layout
.
High Capacity Field Replaceable Transformer
.
Easy-Connect Terminals/Screwless Terminals for
Thermostat Connections
.
24VAC transformer output with common terminal
provides compatibility with electronic thermostat
.
Universal thermostat compatibility
.
100% Factory Tested
.
Extended 3 year warranty
.
RoHS compliance & Environmental Friendly - Do Not
Contain hazardous substances (heavy metals such as
lead, mercury, cadmium etc).
APPLICATION
The
series multi-zone circulator controller is
operated by low voltage thermostats or any other low
voltage controllers having an SPST switching action.
The
controller provides intermediate switching
to permit up to six circulators and a boiler operating
control in a multi-zone hydronic heating system.
Intelligent Linking System (
) allows unlimited
zone expansion with additional
controllers.
Field selectable priority with protection timer prevents
freeze-ups in the event of a priority zone failure.
Unique power surge protection to avoid damage to
the unit and ensure continuous control operation.
The panel provides EZ screwless terminal blocks for
connections to the thermostats. LED indicators on the
front panel provides functional status and easy
troubleshooting. In addition, a system circulator is
turned on whenever any zone calls for heat.
i-Link
i-Link
i-Link
i-Link
MOUNTING
Mount the
i-Link controller to a suitable surface. Slotted
keyholes and standard holes are provided for mounting
purposes.
ROUGH-IN WIRING
Loosen the screws on the top and bottom of the enclosure
and remove the wiring covers by swinging them away from
the base(grey color) with the edges of the covers as pivot(see
Figure 1).
The base has standard 7/8” (22mm) knockouts which accept
common wiring hardware and conduit fittings. Before
removing the knockouts, check the wiring diagrams and use
the chamber with common voltages.
SPECIFICATIONS
Model:
SP-82
2 Zone Switching Relay
SP-83
3 Zone Switching Relay
SP-84
4 Zone Switching Relay
SP-85
5 Zone Switching Relay
SP-86
6 Zone Switching Relay
Power Supply:
120 VAC, 50/60Hz
Dimensions:
6 3/8”(W) x 6 5/8”(H) x 2 3/4”(D)
Electrical Switch Rating:
10 A 1/3 HP @ 120VAC
Thermostat Anticipator Setting: 0.18 A
Enclosure:
Flame Retardant Plastic 94V0
Shipping Weight:
SP-82/83
3 lbs.
SP-84/85/86
4 lbs.
CAUTION!
1. Improper installation and operation of this control could result
damage to the equipment and possibly even personal injury. All
wiring must comply with national and local electrical codes,
ordinances, and regulations. Use Copper wires only. 120 VAC
wiring must have a minimum temperature rating of 75 C. 12-22
gauge wire is recommended for thermostat and 24 VAC source
connections. 12-18 gauge wire is recommended for 120 VAC
connections. Never connect the load terminals to a load that
takes more current than the amount listed for the relay in the
electrical ratings.
2. To prevent electrical shock hazard, disconnect power supply
before installing.
3. Azel Technologies is not liable for an special, incidental, indirect
or consequential damages resulting from the use of its products.
4. This literature is provided for informational purposes only.